The Argus II prosthesis facilitates reaching and grasping tasks: a case series

نویسندگان

  • Aachal Kotecha
  • Joe Zhong
  • David Stewart
  • Lyndon da Cruz
چکیده

BACKGROUND To evaluate the reach-to-grasp performance of patients fitted with an epiretinal artifical retina device. METHODS This was a hospital-based case series consisting of six patients fitted with the Argus II (Second Sight Medical Products Inc, California, USA) retinal prosthesis. Participants were asked to reach out and pick up a high-contrast cuboid object with the prosthesis in the 'On', 'Off' or 'Scrambled' setting presented in a randomised order. The 'Scrambled' setting consisted of a random, scattered signal presented to the prosthesis. The session was repeated after a 4-6 week period. Hand movements were measured using motion detection cameras. The number of successful object grasps was calculated. RESULTS The number of successful grasps was greater with the prosthesis in the 'On' setting (visit 1: median [interquartile range] percentage success: 'Off' = 0 [0 to 50]%, 'On' = 69 [67 to 95]%, 'Scrambled' = 59 [42 to 95]%; Friedman Chi-squared test statistic 6.5, p = 0.04; visit 2 median [IQR] percentage success: 'Off' = 0 [0 to 25]%, 'On' = 69 [53 to 100]%, 'Scrambled' = 28 [13 to 63]%; Friedman Chi-squared test statistic 8.4, p= 0.02). CONCLUSIONS The use of an electronic retinal prosthesis facilitates reach-and-grasp performance. Further work should explore how performance can be improved with targeted rehabilitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years

OBJECTIVE The purpose of this analysis was to compare observer-rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. METHODS The Functional Low-Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow-up of 36 months. FLORA is a mul...

متن کامل

Visual and Non-Visual Navigation in Blind Patients with a Retinal Prosthesis

Human adults with normal vision can combine visual landmark and non-visual self-motion cues to improve their navigational precision. Here we asked whether blind individuals treated with a retinal prosthesis could also benefit from using the resultant new visual signal together with non-visual information when navigating. Four patients (blind for 15-52 years) implanted with the Argus II retinal ...

متن کامل

Influence of the type of training task on intermanual transfer effects in upper-limb prosthesis training: A randomized pre-posttest study

Intermanual transfer, the transfer of motor skills from the trained hand to the untrained hand, can be used to train upper limb prosthesis skills. The aim of this study was to determine the relation between the magnitude of the intermanual transfer effect and the type of training task. The used tasks were based on different aspects of prosthetic handling: reaching, grasping, grip-force producti...

متن کامل

Assessment of MRI issues for the Argus II retinal prosthesis.

OBJECTIVE The objective was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, heating, artifacts and functional alterations) at 1.5 T and 3 T for the Argus II Retinal Prosthesis (Second Sight Medical Products, Sylmar, CA, USA). MATERIALS AND METHODS Standardized protocols were used to assess magnetic field interactions (translational attraction and torque; 3 T,...

متن کامل

Endoscope-Assisted and Controlled Argus II Epiretinal Prosthesis Implantation in Late-Stage Retinitis Pigmentosa: A Report of 2 Cases

Several different approaches for restoring sight in subjects who are blind due to outer retinal degeneration are currently under investigation, including stem cell therapy, gene therapy, and visual prostheses. Although many different types of visual prostheses have shown promise, to date, the Argus II Epiretinal Prosthesis System, developed in a clinical setting over the course of 10 years, is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014