Vibration Control of a Power Transmission Tower with Pounding Tuned Mass Damper under Multi-Component Seismic Excitations
نویسندگان
چکیده
In this paper, the two-dimensional vibration controls of a power transmission tower with a pounding tuned mass damper (PTMD) under multi-component seismic excitations are analyzed. A three-dimensional finite element model of a practical power transmission tower is established in ABAQUS (Dassasult Simulia Company, Providence, RI, USA). The TMD (tuned mass damper) and PTMD are simulated by the finite element method. The response of the transmission tower with TMD and PTMD are analyzed, respectively. To achieve optimal design, the influence of the mass ratio, ground motion intensity, gap, and incident angle of seismic ground motion are investigated, respectively. The results show that the PTMD is very effective in reducing the vibration of the transmission tower in the longitudinal and transverse directions. The reduction ratio increases with the increase of the mass ratio. The ground motion intensity and gap have no obvious influence on the reduction ratio. However, the incident angle has a significant influence on the reduction ratio.
منابع مشابه
Wind-induced Vibration Optimal Control for Long Span Transmission Tower-line System
In this paper, tuned mass dampers with optimal parameters for long span transmission tower-line system are investigated. Equations of motion for a structure-TMD system are derived, and the parameters of TMD, stiffness and damping are optimized, respectively. According to a real project, three-dimensional finite element models of both transmission tower and transmission tower-line system are cre...
متن کاملAssessment of Semi-Active Tunes Mass Damper Application in Suppressing Seismic-Induced Vibration of an Existing Jacket Platform
In this study, mass, stiffness and damping matrices of the Nosrat jacket; located in Persian Gulf; equipped with Semi Active Tuned Mass Damper (SATMD) system have been derived after modeling the structure in SACS software. Owing to huge number of the degrees of freedom in the model, computation of on-line control of SATMD was time consuming. For this purpose, the size of the model was reduced i...
متن کاملDynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review
This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lin...
متن کاملOptimum Parameters for Tuned Mass Damper Using Shuffled Complex Evolution (SCE) Algorithm
This study is investigated the optimum parameters for a tuned mass damper (TMD) under the seismic excitation. Shuffled complex evolution (SCE) is a meta-heuristic optimization method which is used to find the optimum damping and tuning frequency ratio for a TMD. The efficiency of the TMD is evaluated by decreasing the structural displacement dynamic magnification factor (DDMF) and acceleration ...
متن کاملA RELIABILITY APPROACH TO COMPARE OPTIMAL SEISMIC DESIGNS OF MULTIPLE-TUNED-MASS-DAMPER
Passive systems are preferred tools for seismic control of buildings challenged by probabilistic nature of the input excitation. However, other types of uncertainty still exist in parameters of the control device even when optimally tuned. The present work concerns optimal design of multiple-tuned-mass-damper embedded on a shear building by a number of meta-heuristics. They include well-known g...
متن کامل