Analysis of intraocular lens surface properties with atomic force microscopy.

نویسندگان

  • Marco Lombardo
  • Maria P De Santo
  • Giuseppe Lombardo
  • Riccardo Barberi
  • Sebastiano Serrao
چکیده

PURPOSE To analyze the surface optics of 4 currently available intraocular lenses (IOLs) with atomic force microscopy. SETTING Licryl Laboratory, University of Calabria, Rende, Italy. METHODS The surface roughness and topography of poly(methyl methacrylate) (PMMA), silicone, hydrophobic, and hydrophilic acrylic IOLs were evaluated with atomic force microscopy in contact mode. The analysis was performed in a liquid environment using cantilevers with a 0.01 Newtonw/meter nominal elastic constant. Measurements were made over areas of 10 microm2 on different locations of the posterior optic surface of the IOL. RESULTS Atomic force microscopy permitted high-resolution imaging of IOL optic surface characteristics. Surface topography showed different features with respect to the lens biomaterial. The root-mean-square roughness of the IOL optic surface was significantly different between lenses of various materials (P < .001). The hydrophobic acrylic and silicone IOLs had the lowest mean surface roughness, 3.8 nm +/- 0.2 (SD) and 4.0 +/- 0.5 nm, respectively, and the 2 PMMA IOLs had the highest mean surface roughness, 6.6 +/- 0.3 nm and 7.0 +/- 0.6 nm. CONCLUSIONS Atomic force microscopy was effective and accurate in analyzing IOL optics. The surface topography of IOLs may vary with different manufacturing processes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Intraocular Lenses Surface Roughness by Atomic Force Microscopy

The aim of this study was to evaluate the surface roughness of intraocular lenses (IOLs) generated by the manufacturing process and to determine the roughness parameters of 3D surface using atomic force microscopy (AFM). Intraocular lenses commercially available from a single manufacturer: Pharmacia & Upjohn Co. were investigated. Three intraocular lenses, model 911A CeeOn Edge, were analyzed o...

متن کامل

Surface modification of PMMA IOLs by the immobilization of hydroxyethyl methacrylate for improving the biocompatibility

To improve biocompatibility of hydrophobic polymethyl methacrylate intraocular lens (PMMA IOL), 2-hydroxyethyl methacrylate (HEMA) was immobilized by UV-induced graft copolymerization method. The hydrophilicity and chemical composition of the PMMA IOL surface after each step of surfaces modification were analyzed by contact angle (CA) and X-ray photoelectron spectroscopy (XPS). The morphology o...

متن کامل

Posterior capsular opacification and intraocular lens surface micro-roughness characteristics: an atomic force microscopy study.

OBJECTIVE Surface roughness parameters of various intraocular lenses (IOLs) biomaterials using atomic force microscopy (AFM) are compared. Variation, if any, in the micro-roughness properties of different IOLs made up of the same biomaterial is also explored. Retrospective analysis of posterior capsular opacification (PCO) incidence has been followed up for a period of four years post IOL impla...

متن کامل

Fabrication of nonfouling, bactericidal, and bacteria corpse release multifunctional surface through surface-initiated RAFT polymerization

Infections after surgery or endophthalmitis are potentially blinding complications caused by bacterial adhesion and subsequent biofilm formation on the intraocular lens. Neither single-function anti-adhesion surface nor contacting killing surface can exhibit ideal antibacterial function. In this work, a novel (2-(dimethylamino)-ethyl methacrylate-co-2-methacryloyloxyethyl phosphorylcholine) (p ...

متن کامل

Comparison of poly (methyl methacrylate) and acrylic hydrophobic intraocular lens surface irregularities using atomic force microscopy

Background: Posterior capsule opacification (PCO) is a very frequent complication of phacoemulsification surgery in patients undergoing cataract extraction. This has led to modifications in design and material of intraocular lenses (IOLs). There is increasing evidence suggesting that foldable acrylic hydrophobic IOLs are associated with lower PCO incidence. However, traditional rigid poly methy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2006