A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.

نویسندگان

  • Brett D Crist
  • Afshin Khalafi
  • Scott J Hazelwood
  • Mark A Lee
چکیده

OBJECTIVES The angled blade plate has been the historical standard in fixed-angle extramedullary subtrochanteric femur fracture fixation, but it requires an extensile lateral approach to the femur. Little formal evaluation exists for specifically designed percutaneous extramedullary implants. The purpose of this study was to compare 3 locked plating constructs, all with percutaneous insertion capability, with the standard 95-degree angled blade plate to determine whether specifically designed fixed-angle extramedullary implants for subtrochanteric femur fractures were biomechanically comparable to the angled blade plate. METHODS Forty composite adult femurs were divided into 4 equal groups. The constructs evaluated included a 95-degree angled blade plate, a broad 4.5-mm combination locking plate, and a precontoured proximal femoral locking plate (PFLP) with and without an oblique, angled strut or "kickstand" screw. A 30-degree wedge osteotomy was used to create a subtrochanteric fracture gap model. Each specimen underwent axial and torsional stiffness testing along with cyclic axial loading to failure. RESULTS Axial stiffness testing revealed that the PFLP with the "kickstand" screw was the stiffest construct (92.2 +/- 17.4 Nm/m), which was 211% stiffer than the blade plate, 309% stiffer than the broad plate, and 194% stiffer than the PFLP without the kickstand screw. The blade plate had the highest torsional stiffness (2.42 +/- 0.08 Nm/degree), which was 151% stiffer than the broad plate, 128% stiffer than the PFLP with the kickstand, and 138% stiffer than the PFLP without the kickstand screw. The PFLP with the kickstand screw had the least irreversible deformation (6.3 mm), which was 52% less than the broad plate and 61% less than the PFLP without the kickstand screw. CONCLUSIONS Our data reveal that the PFLP with the "kickstand" screw provides more axial stiffness, less torsional stiffness, and equivalent irreversible deformation to cyclic axial loading when compared with the blade plate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Locked Plating: Biomechanics and Biology

Since the early ideas of internal fixation, many different concepts and techniques have been developed for the use in fracture surgery. Each technique has been welcomed by many with excitement while others have suggested caution, locked plating is no exception. Since its advent over 15 years ago many have viewed this as a violation of the strict AO principles of anatomic reduction and rigid fix...

متن کامل

Fixation of Supracondylar Femoral Fractures: a Biomechanical Analysis Comparing 95° Blade Plates and Dynamic Condylar Screws (dcs)

OBJECTIVE To determine, by means of comparative biomechanical tests, whether greater compressive load resistance and flexion is presented by 95° angled blade plates or by dynamic condylar screws (DCS), and to correlate the failure type presented during the tests with each type of plate. METHODS Sixty-five porcine femurs were subjected to 1 cm medial wedge osteotomy, in the metaphysis, to simu...

متن کامل

Proximal Femoral Nail - A Minimally Invasive Method for Stabilization of Pertrochanteric and Subtrochanteric Femoral Fractures

Fractures of the proximal femur are a big challenge in traumatology. Rapid strides in implant and instrumentations in quest of ideal fixation of pertrochanteric and subtrochanteric femoral fractures have made various options available like Fixed-angled nail plate, Screw plates, Angled blade plate, Dynamic Hip Screw etc. The present study aims to study the role of standard PFN as a minimal invas...

متن کامل

Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.

OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 23 9  شماره 

صفحات  -

تاریخ انتشار 2009