Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report

نویسندگان

  • Jacob E. Mathew
  • Kelvin Mok
  • Benoit Goulet
چکیده

BACKGROUND Use of computer-assisted insertion of pedicle screws has some advantages owing to the reportedly decreased incidence of pedicle breach and clinical events. Registration-based methods based on preoperative computed tomography imaging, 2D fluoroscopy, and 3D fluoroscopy are the most popular, however each has its limitations. O-arm-based navigation, which uses intraoperative acquisition and registration of navigated images, may overcome many of these disadvantages. We set out to study the clinical accuracy and navigational accuracy for pedicle screw insertion using our recently acquired O-arm and present our preliminary findings. METHODS The first 26 patients operated consecutively for L4-5 fusion were included in the study. O-arm-based navigation was used to insert the pedicle screws. Postoperative computed tomography images were acquired and assessed for pedicle breach and anterior cortical perforation. Planned trajectories of each screw were compared with the actual trajectories in the postoperative images to assess navigational accuracy in both axial and sagittal planes. RESULTS A total of 104 screws were inserted. One screw (1%) breached the pedicle laterally. Nonsignificant anterolateral cortical perforations were noted in 7 screws (6.7%), all of which occurred at L5 level. The mean axial and sagittal navigational error was 2.3° (±1.7) and 3.1° (±2.3), respectively. There were no significant differences in the errors between L4 or L5 level. The occurrence of anterior perforation correlated with the degree of axial (P = .02) but not sagittal (P = .12) navigational error. There were no clinical events related to the screw insertion. CONCLUSION Use of O-arm-guided pedicle screw insertion was associated with low incidence of pedicle breach (1%) and a low range of navigational error in both sagittal and axial planes. Anterolateral vertebral body perforation was higher at L5 without any negative clinical events. Despite the high need for technical support, we found that O-arm was a very efficient tool for accurate pedicle screw insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of CT-based navigation system for pedicle screw placement.

The incidence of pedicle screw breech varies based on anatomic location, body habitus, surgeon experience, spinal deformity, and surgical technique. Pedicle breeches have been reported to occur in up to 40% of screws. The purpose of this retrospective study was to compare the rates of revision of pedicle screw placement when using intraoperative C-arm vs O-arm (Medtronic, Memphis, Tennessee) as...

متن کامل

Commentary: Utility of the O-Arm in spinal surgery

BACKGROUND More studies report the intraoperative benefits vs. risks of utilizing the O-Arm in performing pedicle screw insertion in spinal surgery. METHODS/RESULTS Several studies document the utility of CT-guided O-arm placement of pedicle/lateral mass screws. Singh et al. documented the efficacy of CT guided-O Arm placement of pedicle screws and lateral mass screws in the upper cervical sp...

متن کامل

Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion

BACKGROUND A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS By use of a hypothetical "perfect screw," a ...

متن کامل

Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion.

Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 ve...

متن کامل

Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?

BACKGROUND Pedicle screws are biomechanically superior over other spinal fixation devices. When improperly positioned, they lose this advantage and put adjacent structures at risk. Accurate placement is therefore critical. Postoperative computed tomography (CT) scans are the imaging gold standard and have shown malposition rates ranging from 2% to 41%. The O-arm (Medtronic Navigation, Louisvill...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013