BACKGROUND AND PURPOSE Time-of-flight MR angiography (TOF MRA), with its advantage of high spatial resolution, is widely used for visualization of intracranial arteries. Fat signal intensity from bone marrow can interfere with vessel signal intensity, especially in maximum intensity projection reconstructions. Use of a technique such as fat saturation or water excitation can reduce this signal intensity. METHODS Ten volunteers were included in this study. TOF MRA was performed by using spoiled gradient echo sequences on a 1.5-T MR unit either with or without water excitation. Water excitation was performed by using a binomial excitation pulse pair, with a null in the excitation profile at the fat frequency to obtain fat suppression. Two blinded neuroradiologists then judged the images. Additional studies by using a phantom with a flow of about 2 mL/s were performed under the same conditions. Image quality obtained with and that without water excitation was graded as similar by both neuroradiologists. RESULTS As the main finding, the sequences by using water excitation revealed an important pitfall: apparent carotid artery stenosis was detected in 4/10 and occlusions in 1/10 cases. Use of a flow phantom could reveal the same pitfall. Intracranial vessel disease was excluded in all volunteers by using Doppler sonography. CONCLUSION The type of water excitation tested here can induce significant artifacts in cerebral TOF MRA. These artifacts can be misinterpreted as carotid artery stenosis or even occlusion, whereas the benefit brought by water excitation with respect to fat suppression is less significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A pitfall in detection of intracranial unruptured aneurysms on three-dimensional phase-contrast MR angiography.

We report three cases of intracranial unruptured aneurysm evaluated with MR angiography using both three-dimensional time-of-flight and three-dimensional phase-contrast techniques. It has been said that the phase-contrast technique has advantages over the time-of-flight technique in the detection of intracranial aneurysms. However, in our three cases, three-dimensional time-of-flight MR angiogr...

متن کامل

Evaluation of cerebral vasoreactivity by three-dimensional time-of-flight magnetic resonance angiography.

BACKGROUND AND PURPOSE Cerebral vasoreactivity is an important indicator of the reserve capacity of the cerebral circulation. To make a quantitative analysis of cerebral vasoreactivity in individual major arterial territories, we evaluated the response to acetazolamide using three-dimensional time-of-flight magnetic resonance angiography. METHODS We examined 10 healthy volunteers and 6 patien...

متن کامل

INVESTIGATION OF NON-LINEAR CYCLES’ PROPERTIES IN STRUCTURES SUBJECTED TO ENDURANCE TIME EXCITATION FUNCTIONS

Endurance Time Method (ET) is a dynamic analysis in which structures are subjected to intensifying accelerograms that are optimized in a way that seismic performance of structures can be estimated at different hazard levels with the best possible accuracy. For the currently available ET accelerograms, regardless of the shaking characteristic, an excitation level is recognized as a representativ...

متن کامل

Transradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note

Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...

متن کامل

Large-cohort comparison between three-dimensional time-of-flight magnetic resonance and rotational digital subtraction angiographies in intracranial aneurysm detection.

BACKGROUND AND PURPOSE The value of MR angiography varies in diagnosis of intracranial aneurysms due to the difference of equipment and imaging technique. This study was to compare the effectiveness of 3-dimensional time-of-flight MR angiography at 3 T and rotational digital subtraction angiography, both with volume rendering (VR), in detecting intracranial aneurysms. METHODS One hundred thir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2005