The effect of induced intraocular straylight on perimetric tests.

نویسندگان

  • Ciara Bergin
  • Tony Redmond
  • Neil Nathwani
  • Gay Mary Verdon-Roe
  • David P Crabb
  • Roger S Anderson
  • David F Garway-Heath
چکیده

PURPOSE To investigate the effect of intraocular straylight (IOS) on threshold measurements made by four types of perimetry: standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, flicker-defined form (FDF) perimetry, and the Moorfields Motion Displacement Test (MDT). METHODS Six healthy young (21-29 years) psychophysically experienced observers were tested five times with each perimeter, each time with one of five different white opacity filters (WOFs), to induce various levels of IOS. Each WOF gave rise to an increase in IOS, measured with a straylight meter, of between 10% and 200% from baseline and ranging in effect from normal ageing to significant cataract. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the standard deviation of normative values) for each instrument. RESULTS Average SAP, FDT, and FDF thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%), whereas MDT remained largely unaffected over the same range of straylight levels. CONCLUSIONS The Moorfields MDT shows greater resilience to the effects of additional straylight compared with SAP, FDT, or FDF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. R...

متن کامل

Optical Scattering Measurements of Laser Induced Damage in the Intraocular Lens

This study optically determines whether the amount of light scatter due to laser-induced damage to the intraocular lens (IOL) is significant in relation to normal straylight values in the human eye. Two IOLs with laser-induced damage were extracted from two donor eyes. Each IOL had 15 pits and/or cracks. The surface area of each pit was measured using a microscope. For 6 pits per intraocular le...

متن کامل

Comparison of ocular straylight after implantation of multifocal intraocular lenses.

UNLABELLED A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The IOLs were categorized based on their material characteristics; that is, hydrophobicity and presen...

متن کامل

Effect of diabetic retinopathy and diabetes on the intraocular straylight in pseudophakic eyes

BACKGROUND The aim of this study was to prove the relationship between the intraocular straylight level and diabetic retinopathy (DR) according to disease severity. Also, we aimed to evaluate whether diabetes mellitus (DM) per se could be a risk factor of increased intraocular straylight although we did not rely on a definite sign of DR in this study. METHODS In this prospective comparative s...

متن کامل

Method for in vitro assessment of straylight from intraocular lenses.

Ocular straylight has been measured by means of psychophysical methods over the years. This approach gives a functional parameter yielding a straight comparison with optically defined light scattering, and the point-spread-function. This is of particular importance when the effect of intraocular lenses (IOLs) on postoperative straylight is sought. An optical system for straylight measurements o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2011