Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

نویسندگان

  • Jong Hyun Cha
  • Myeong Ho Moon
  • Yong Hae Lee
  • In Chang Koh
  • Kyu Nam Kim
  • Chang Gyun Kim
  • Hoon Kim
چکیده

BACKGROUND The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. METHODS This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30) or the medial wall (group M, n=30). The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters. RESULTS Varying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568-0.788; R2=32.2%-62.1%). CONCLUSIONS Both the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>0.9 cm3) occurred not infrequently despite the presence of a small orbital defect (<1.9 cm2). Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures.

PURPOSE To analyze the correlation between the volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures. MATERIALS AND METHODS Patients with secondary enophthalmos due to unilateral orbital floor and wall fractures were recruited. Computed tomography-assisted measurements of both orbits as well as of the amount of enophthalmos were performed. The...

متن کامل

مقایسه دقت رادیوگرافی واترز با CT اسکن در تشخیص شکستگیهای ناحیه Midface

Background and Aim: In recent years, CT scan has become available as an alternative to conventional radiography. To date, the utility of Waters view in detecting midface fractures has been rarely evaluated. The aim of this study was to compare the diagnostic accuracy and reliability of Waters radiography with CT scan in detecting midface fractures. Materials and Methods: In this tests evaluatio...

متن کامل

بررسی ده ساله شکستگی‌های اوربیت در یک مرکز آموزشی

Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 !mso]> st1":*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tst...

متن کامل

High-performance three-dimensional maneuvers control in the area of spacecraft

Contemporary research is improving techniques to maneuvers control in the area of spacecraft. In the aspect of further development of investigations, a high-performance strategy of maneuvers control is proposed in the present research to be applicable to deal with a class of the aforementioned spacecrafts. In a word, the main subject behind the research is to realize a high-performance three-di...

متن کامل

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

BACKGROUND The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. METHODS Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2017