Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathing.
نویسندگان
چکیده
The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical characteristics of the helmet (large internal volume and high compliance) might impair patient-ventilator interactions compared with standard face mask. Breathing pattern, CO(2) clearance, indexes of inspiratory muscle effort and patient-ventilator asynchrony, and dyspnea were measured at different levels of PSV delivered by face mask and helmet in six healthy volunteers before (load-off) and after (load-on) application of a linear resistor. During load-off, no differences in breathing pattern and inspiratory muscle effort were found. During load-on, the use of helmet to deliver pressure support increased inspiratory muscle effort and patient-ventilator asynchrony, worsened CO(2) clearance, and increased dyspnea compared with standard face mask. Autocycled breaths accounted for 12 and 25% of the total minute ventilation and for 10 and 23% of the total inspiratory muscle effort during mask and helmet PSV, respectively. We conclude that PSV delivered by helmet interface is less effective in unloading inspiratory muscles compared with PSV delivered by standard face mask. Other ventilatory assist modes should be tested to exploit to the most the potential benefits offered by the helmet.
منابع مشابه
Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.
BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive resp...
متن کاملContinuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.
BACKGROUND Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced AR...
متن کاملWaiting to Exhale: Optimizing Noninvasive Synchrony in COPD?
Noninvasive ventilation (NIV) has become a widely used modality for many types of respiratory conditions. Some advantages of NIV include lower sedation requirement, preservation of cough and pulmonary clearance, and reduced frequency of ventilator-associated pneumonia.1 NIV has been used successfully in patients with cardiogenic pulmonary edema.2-4 It has been shown to decrease intubation durat...
متن کاملComparison of noninvasive ventilation by sequential use of mask and helmet versus mask in acute exacerbation of chronic obstructive pulmonary disease: a preliminary study.
BACKGROUND Noninvasive positive pressure ventilation (NPPV) using a face mask is the ventilatory mode of choice in selected patients experiencing acute exacerbation of chronic obstructive pulmonary disease (COPD). A high incidence of intolerance limits the use of this approach. OBJECTIVE To evaluate the sequential use of mask and helmet during NPPV in patients with severe exacerbation of COPD...
متن کاملNoninvasive ventilation with helmet versus control strategy in patients with acute respiratory failure: a systematic review and meta-analysis of controlled studies
BACKGROUND Noninvasive ventilation (NIV) has proved to be a useful technique for breathing support. However, complications, discomfort, and failure of NIV were commonly caused by the mask. Therefore, the helmet was developed to improve performance and reduce complications; however, there has been no conclusive results on its effect until now. Thus, we performed a systematic review and meta-anal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 99 4 شماره
صفحات -
تاریخ انتشار 2005