Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis.
نویسندگان
چکیده
We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the application of the technique to peripheral ABP waveforms obtained via radial artery catheterization with simultaneous thermodilution CO measurements in 15 intensive care unit patients in which CO was changing because of disease progression and therapy. With the latter data set, we compared the application of the technique to noninvasive peripheral ABP waveforms obtained via a finger-cuff photoplethysmography system with simultaneous Doppler ultrasound CO measurements made by an expert in 10 healthy subjects during pharmacological and postural interventions. We report an overall CO root-mean-squared normalized error of 15.3% with respect to the invasive hemodynamic data set and 15.1% with respect to the noninvasive hemodynamic data set. Moreover, the CO errors from the invasive and noninvasive hemodynamic data sets were only mildly correlated with mean ABP (rho = 0.41, 0.37) and even less correlated with CO (rho = -0.14, -0.17), heart rate (rho = 0.04, 0.19), total peripheral resistance (rho = 0.38, 0.10), CO changes (rho = -0.26, -0.20), and absolute CO changes (rho = 0.03, 0.38). With further development and successful prospective testing, the technique may potentially be employed for continuous hemodynamic monitoring in the acute setting such as critical care and emergency care.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملTRANSLATIONAL PHYSIOLOGY Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
Lu, Zhenwei, and Ramakrishna Mukkamala. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. J Appl Physiol 101: 598–608, 2006; doi:10.1152/japplphysiol.01488.2005.—We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملRelating Noninvasive Cardiac Output and Total Peripheral Resistance Estimates to Physical Activity in an Ambulatory Setting
The prevalence and cost of heart disease indicate the need for better methods of detecting, diagnosing and treating this pervasive problem. Appropriate monitoring outside of the hospital can potentially lead to earlier diagnosis and reduced costs. We use electrocardiogram (ECG) and continuous arterial blood pressure (ABP) data collected in an ambulatory setting to examine two important cardiova...
متن کاملNoninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
BACKGROUND Monitoring of cardiac output and blood pressure are standard procedures in critical care medicine. Traditionally, invasive techniques like pulmonary artery catheter (PAC) and arterial catheters are widely used. Invasiveness bears many risks of deleterious complications. Therefore, a noninvasive reliable cardiac output (CO) and blood pressure monitoring system could improve the safety...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 101 2 شماره
صفحات -
تاریخ انتشار 2006