In vivo corneal high-speed, ultra high-resolution optical coherence tomography.

نویسندگان

  • Viki Christopoulos
  • Larry Kagemann
  • Gadi Wollstein
  • Hiroshi Ishikawa
  • Michelle L Gabriele
  • Maciej Wojtkowski
  • Vivek Srinivasan
  • James G Fujimoto
  • Jay S Duker
  • Deepinder K Dhaliwal
  • Joel S Schuman
چکیده

OBJECTIVE To introduce new corneal high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT) technology that improves the evaluation of complicated and uncomplicated cataract, corneal, and refractive surgical procedures. DESIGN This case series included a control subject and 9 eyes of 8 patients who had undergone phacoemulsification, Descemet membrane stripping endokeratoplasty, corneal implantation for keratoconus, and complicated and uncomplicated laser in situ keratomileusis. These eyes underwent imaging using a prototype ophthalmic hsUHR-OCT system. All the scans were compared with conventional slitlamp biomicroscopy. RESULTS Cross-sectional hsUHR-OCT imaging allowed in vivo differentiation of corneal layers and existing pathologic abnormalities at ultrahigh axial image resolution. These images illustrate the various incisional and refractive interfaces created with corneal procedures. CONCLUSIONS The magnified view of the cornea using hsUHR-OCT is helpful in conceptualizing and understanding basic and complicated clinical pathologic features; hsUHR-OCT has the potential to become a powerful, noninvasive clinical corneal imaging modality that can enhance surgical management. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00343473.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

OBJECTIVE To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS In vivo images of the retina, the optic nerve he...

متن کامل

Ultra-high speed and ultra-high resolution spectral-domain optical coherence tomography and optical Doppler tomography in ophthalmology.

We present ultra-high resolution optical coherence tomography (OCT) structural intensity and optical Doppler tomography (ODT) flow velocity images of the human retina in vivo. The ultra-high speed OCT system is based on Spectral Domain or Fourier Domain technology, which provides a sensitivity advantage over conventional OCT of more than 2 orders of magnitude. This sensitivity improvement allow...

متن کامل

Ultra-high resolution and long scan depth optical coherence tomography with full-phase detection for imaging the ocular surface

We used a unique combination of four state-of-the-art technologies to achieve a high performance spectral domain optical coherence tomography system suitable for imaging the entire ocular surface. An ultra-high resolution, extended depth range, full-phase interferometry, and high-speed complementary metal-oxide semiconductor transistor camera detection provided unprecedented performance for the...

متن کامل

Automated 3D Reconstruction and Segmentation from Optical Coherence Tomography

Ultra-High Resolution Optical Coherence Tomography is a novel imaging technology that allows non-invasive, high speed, cellular resolution imaging of anatomical structures in the human eye, including the retina and the cornea. A three-dimensional study of the cornea, for example, requires the segmentation and mutual alignment of a large number of two-dimensional images. Such segmentation has, u...

متن کامل

Vertical and Horizontal Corneal Epithelial Thickness Profile Using Ultra-High Resolution and Long Scan Depth Optical Coherence Tomography

PURPOSE To determine the vertical and horizontal thickness profiles of the corneal epithelium in vivo using ultra-long scan depth and ultra-high resolution spectral domain optical coherence tomography (SD-OCT). METHODS A SD-OCT was developed with an axial resolution of ∼ 3.3 µm in tissue and an extended scan depth. Forty-two eyes of 21 subjects were imaged twice. The entire horizontal and ver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 125 8  شماره 

صفحات  -

تاریخ انتشار 2007