Comparative study of five blood cardioplegia systems.
نویسندگان
چکیده
Five blood cardioplegia delivery systems (Gish Straight Shot, Sorin BCD Advanced, Avecor MYOtherm, Baxter-Bentley HE-30, and Baxter-Bentley HE-30 Gold) were evaluated with respect to ease of rapid priming, coefficient of heat exchange, pressure drop, bubble trap capacity, and priming volume. Each system was placed in a roller pump circuit consisting of source and collection reservoirs, cardioplegia solution, and pre-post system pressure and temperature monitoring sites. A trial was performed on four units of each brand by first priming the circuit with 0.9% NaCl at 200 ml/min. Bovine blood (hematocrit 22%) was then introduced simulating use during bypass. Pressure drops across the heat exchanger were measured at flows of 200, 300, and 400 ml/min and at temperatures of 37 degrees, 19 degrees, and 4 degrees C. Coefficient of heat exchange was determined at 300 ml/min flow. Air was infused into the system to quantify the bubble trap capacity of the heat exchanger module. Priming volume of the entire system and of the heat exchanger module were determined by draining each into a graduated cylinder. The Sorin system had significantly less priming volume when compared to all others. The HE-30 units had significantly higher heat exchange coefficients compared to all other systems. Variability was noted in pressure drop at the highest flows and lowest temperatures.
منابع مشابه
The Cardioprotective Effects of N acetylcysteine as an Additive to the Blood Cardioplegia During Coronary Artery Bypass Grafting
Introduction: During coronary artery bypass graft (CABG) surgery with cardiopulmonary bypass (CPB), the role of cardioplegic solution which results in cardiac arrest, is critical. This study was planned to evaluate the clinical impacts of N acetylcysteine (NAC) enriched cold-blood cardioplegia on early reperfusion injury in patients with ischaemic heart disease undergoing CABG Methods: In a...
متن کاملWarm reperfusion and myocardial protection.
BACKGROUND The aim of this study was to determine whether warm reperfusion improves myocardial protection with cardiac troponin I as the criteria for evaluating the adequacy of myocardial protection. METHODS One hundred five patients undergoing first-time elective coronary bypass surgery were randomized to one of three cardioplegic strategies of either (1) cold crystalloid cardioplegia follow...
متن کاملCardioprotection with esmolol cardioplegia: efficacy as a blood-based solution.
OBJECTIVES Current cardiac surgery patients are older, sicker, with more diffuse disease and hence a reduced tolerance to ischaemia-reperfusion injury. We previously demonstrated that esmolol, an ultra-short-acting β-blocker, can be used as an arresting agent at high (millimolar) concentrations, and that a crystalloid-based esmolol cardioplegia afforded cardioprotection at least equivalent to h...
متن کاملWarm blood hyperkalaemic reperfusion ('hot shot') prevents myocardial substrate derangement in patients undergoing coronary artery bypass surgery.
OBJECTIVE A significant metabolic derangement occurs in the ischaemic-reperfused heart of patients undergoing coronary artery bypass surgery using cold blood cardioplegia. The aim of the present study was to investigate whether this effect could be reversed by complementing cold blood cardioplegia with a short terminal exposure of warm blood hyperkalaemic cardioplegia ('hot shot'). METHODS Th...
متن کاملCardioplegia and Cardiac Function
................................................................................................... 7 LIST OF ORIGINAL ARTICLES .................................................................. 9 ABBREVIATIONS ......................................................................................... 10 INTRODUCTION ...................................................................................
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 26 4 شماره
صفحات -
تاریخ انتشار 1994