Anaphylactoid reaction during first hemofiltration with a PUREMA polysulfone membrane.
نویسندگان
چکیده
Adverse reactions during hemodialysis are extremely common and include a wide range of clinical presentations from mild to life threatening. We present a case of a 34 year old woman in the Burn Intensive Care Unit, who developed acute kidney injury requiring renal replacement therapy. She was placed on continuous veno-venous hemofiltration with the NxStage machine which uses a synthetic PUREMA polyethersulfone filter sterilized by gamma radiation. Within two minutes of initiating hemofiltration, the patient complained of pruritus as well as dyspnea and became flushed and agitated. She subsequently developed hypotension ultimately resulting in cardiopulmonary arrest. Cardiopulmonary resuscitation was initiated and the patient was given epinephrine with return of spontaneous circulation. The following day, the patient was rechallenged with a PUREMA filter, and had a similar reaction with flushing, dyspnea, pruritus and hypotension requiring treatment to be discontinued. The patient was transitioned to the Prismaflex filter, another synthetic membrane, which she tolerated well and continued to utilize through the remainder of her hospital course without complication. Her clinical presentation was consistent with an anaphylactoid reaction, though a tryptase level was not obtained and a radioallergosorbent test performed with membrane material was negative. This case shows the difficulty of identifying the cause of hypersensitivity reactions involving synthetic membranes not sterilized by ethylene oxide, a commonly use sterilizing agent known to cause hypersensitivity reactions. This rare, but potentially fatal reaction has not previously been reported with a PUREMA filter and this case should raise awareness of hypersensitivity reactions with this widely used method of renal replacement therapy.
منابع مشابه
Role of bradykinin in anaphylactoid reactions during hemodialysis with AN69 dialyzers.
In vitro experiments have related anaphylactoid reactions in patients treated with angiotensin-converting enzyme (ACE) inhibitors during dialysis with AN69 membranes to excessive bradykinin generation using this negatively charged dialysis membrane. In the present clinical trial plasma bradykinin levels were followed during the early phase of dialysis in 10 patients, not being treated with ACE ...
متن کاملIn vivo clearance and elimination of nine marker substances during hemofiltration with different membranes.
The handling of low, middle and high molecular weight markers was examined in seven stable dialysis patients during hemofiltration with different membranes. Four membranes were examined in a randomized, crossover order (polysulfone, polyamide, AN69 polyacrylonitrile, Asahi polyacrylonitrile) by measuring plasma and dialysate concentrations of phosphate, creatinine, vitamin B12, beta 2-microglob...
متن کاملAnaphylactoid reactions due to haemodialysis, haemofiltration, or membrane plasma separation.
A previously undescribed anaphylactoid reaction to haemodialysis, haemofiltration, or membrane plasma separation occurred in 15 patients receiving regular dialysis. The illness varied in severity from urticaria, sneezing, and watering of the eyes to severe bronchospasm and cardiovascular collapse, and began within a minute of blood being returned from the dialyser or filtration device to the pa...
متن کاملIs neutrophil gelatinase-associated lipocalin unaffected by convective continuous renal replacement therapy? Definitely … maybe
Two recent studies published in Critical Care reported that plasma [1] and urinary [2] levels of neutrophil gelatinase-associated lipocalin (NGAL), an important biomarker for prediction and diagnosis of acute kidney injury, were not affected by continuous renal replacement therapy (CRRT). The investigators assessed NGAL elimination during continuous venovenous hemofiltration [1] and hemodiafilt...
متن کاملDeterminants of ceftazidime clearance by continuous venovenous hemofiltration and continuous venovenous hemodialysis.
Although several dosage adjustment regimens have been proposed, there is little quantitative information to guide the initiation of ceftazidime therapy in patients who are receiving continuous renal replacement therapy. To determine the clearance of ceftazidime by continuous venovenous hemofiltration (CVVH) and continuous venovenous hemodialysis (CVVHD), we performed controlled clearance studie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of artificial organs
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2013