Computer representation of osteosynthesis stability in locking plates used for the treatment of osteoporotic proximal humerus fractures.
نویسندگان
چکیده
BACKGROUND Proximal humerus fractures are represented as 4-5% of all fractures, with incidence notably growing with age. Since surgical internal fixation in treatment of proximal humeral fractures is used, fractures of osteoporotic bone and choice of plate for their osteosynthesis represent particular problem. The aim of the study was to test two locking plates: Philos plate with locking screws with determinated direction, and Arthrex plate with poliaxial locking screws, using the finite element method. SUBJECTS AND METHODS This study used version 6.10 of Abaqus FEA software package for simulation and fine element analysis of Philos and Artrex plates attached to the osteotomy models of proximal humerus with fracture gap at 0°, 10° and 20° in four types of static load: abduction, adduction, axial compression and flexion. Simulation results of loads in abduction, adduction, axial loads and flexion, were described with the total bone displacement (U) and maximum bone displacement in the fracture gap (Uf). RESULTS When examining the Philos plate in axial load on the bone with fracture gap angle from 0°, 10° and 20° no significant differences between the results for the displacements were observed. Therefore, results for other loads are related to total displacements of the bone only at the angle of 0°. Given that the results of the total bone displacement and maximum bone displacement in the fracture gap with Artrex plate were mostly higher, for comparison with the results of bone displacement in Philos plate it was taken that total bone displacement and maximum displacement in the fracture gap in Artrex plate represent 100% of the total displacement. Philos plate showed 60.71% for abduction, 76.07% for adduction, 102.24% for axial loads and 79.59% for flexion of total bone displacement in Artrex plate, and 60.48% for abduction, 76.07% for adduction, 96.05% for axial load and 79.96% for flexion of maximum displacement in the fracture gap in Artrex plate. CONCLUSIONS Osteosynthesis for osteoporotic fractures of proximal humerus with Philos plate in computer simulation proved to be more stable than with Arthrex plate.
منابع مشابه
The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملMinimal Invasive Approach to Proximal Humerus Fractures with Diaphysis Extension in Elderly
Surgical treatment of proximal humeral fractures with diaphysis extension continues to be a challenge especially in osteoporotic patients. Anatomic locking plates have been used with satisfactory results. The aim of this study was to
متن کاملTension wiring to increase stability of conventional plating for proximal humeral fractures: An alternative to a locking plate
Fixation of comminuted or osteoporotic fractures in the proximal humerus is a challenge for orthopedic surgeons. In the past two decades, locking plates have been used for proximal humeral fracture fixation. However, complications such as loss of reduction have been reported, and the implants are not always available in some regions. Therefore, we describe an alternative procedure involving fix...
متن کاملDisplaced proximal humeral fractures: an Indian experience with locking plates
BACKGROUND The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. METHODS Over two and a half years, 56 pa...
متن کاملThe Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate.
BACKGROUND In the last fifty years since plate and screw osteosynthesis has been implemented in fracture treatment, osteosporotic bone fractures were observed as a special problem. Due to special histologic, anatomic, physical and biomehanic properties of osteoporotic changed bone the laws of biomechanics suggest that stable osteosynthesis for osteoporotic bone is necessary to increase the cont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Psychiatria Danubina
دوره 26 Suppl 2 شماره
صفحات -
تاریخ انتشار 2014