Diagnostic Accuracy of 2D-Shear Wave Elastography for Liver Fibrosis Severity: A Meta-Analysis

نویسندگان

  • Tian’an Jiang
  • Guo Tian
  • Qiyu Zhao
  • Dexing Kong
  • Chao Cheng
  • Liyun Zhong
  • Lanjuan Li
چکیده

PURPOSE To evaluate the accuracy of shear wave elastography (SWE) in the quantitative diagnosis of liver fibrosis severity. METHODS The published literatures were systematically retrieved from PubMed, Embase, Web of science and Scopus up to May 13th, 2016. Included studies reported the pooled sensitivity, specificity, positive and negative predictive values, as well as the diagnostic odds ratio of SWE in populations with liver fibrosis. A bivariate mixed-effects regression model was used, which was estimated by the I2 statistics. The quality of articles was evaluated by quality assessment of diagnostic accuracy studies (QUADAS). RESULTS Thirteen articles including 2303 patients were qualified for the study. The pooled sensitivity and specificity of SWE for the diagnosis of liver fibrosis are as follows: ≥F1 0.76 (p<0.001, 95% CI, 0.71-0.81, I2 = 75.33%), 0.92 (p<0.001, 95% CI, 0.80-0.97, I2 = 79.36%); ≥F2 0.84 (p = 0.35, 95% CI, 0.81-0.86, I2 = 9.55%), 0.83 (p<0.001, 95% CI, 0.77-0.88, I2 = 86.56%); ≥F3 0.89 (p = 0.56, 95% CI, 0.86-0.92, I2 = 0%), 0.86 (p<0.001, 95% CI, 0.82-0.90, I2 = 75.73%); F4 0.89 (p = 0.24, 95% CI, 0.84-0.92, I2 = 20.56%), 0.88 (p<0.001, 95% CI, 0.84-0.92, I2 = 82.75%), respectively. Sensitivity analysis showed no significant changes if any one of the studies was excluded. Publication bias was not detected in this meta-analysis. CONCLUSIONS Our study suggests that SWE is a helpful method to appraise liver fibrosis severity. Future studies that validate these findings would be appropriate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive assessment of liver fibrosis using two-dimensional shear wave elastography in patients with autoimmune liver diseases

AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography (2D-SWE) for the non-invasive assessment of liver fibrosis in patients with autoimmune liver diseases (AILD) using liver biopsy as the reference standard. METHODS Patients with AILD who underwent liver biopsy and 2D-SWE were consecutively enrolled. Receiver operating characteristic (ROC) curves were constructe...

متن کامل

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Diagnostic role of real-time shear wave elastography on staging of liver fibrosis

Background: Shear wave elastography (SWE) is one of newly-developed methods. Our meta-analysis was aimed to clarify whether SWE could be used as a diagnostic biomarker of liver fibrosis. Methods: We searched the potential articles in databases of PubMed, EMbase and Google Scholar. The discrimination of F0 from F1/4 (F≥1), F0/1 from F2/4 (F≥2), F0/2 from F3/4 (F≥3), and F0/3 from F4 (F≥4) were t...

متن کامل

Performance of transient elastography for the staging of liver fibrosis: a meta-analysis.

BACKGROUND & AIMS Transient elastography has been studied in a multitude of liver diseases for the staging of liver fibrosis with variable results. A meta-analysis was performed to assess the overall performance of transient elastography for the diagnosis of liver fibrosis and to analyze factors influencing the diagnostic accuracy. METHODS Literature databases and international conference abs...

متن کامل

Assessment of biopsy‐proven liver fibrosis by two‐dimensional shear wave elastography: An individual patient data‐based meta‐analysis

Two-dimensional shear wave elastography (2D-SWE) has proven to be efficient for the evaluation of liver fibrosis in small to moderate-sized clinical trials. We aimed at running a larger-scale meta-analysis of individual data. Centers which have worked with Aixplorer ultrasound equipment were contacted to share their data. Retrospective statistical analysis used direct and paired receiver operat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016