Accurate measurements of infinite dilution activity coefficients using gas chromatography with static-wall-coated open-tubular columns.

نویسندگان

  • Qianqian Xu
  • Baogen Su
  • Xinyi Luo
  • Huabin Xing
  • Zongbi Bao
  • Qiwei Yang
  • Yiwen Yang
  • Qilong Ren
چکیده

Wall-coated open-tubular (WCOT) columns provide higher column efficiency and lower solute interfacial adsorption effect than packed columns. However, previous efforts used to measure the infinite dilution activity coefficient (γ(∞)) via a chromatographic technique have used packed columns, because the low carrier gas flow rate (U) and the small stationary phase amount (n(2)) in WCOT columns raise large errors. By rationally revising the γ(∞)-calculation equation for static-wall-coated open-tubular column, we observed that U and n(2) are not necessarily needed and the resulting error could be reduced, and WCOT column gas chromatography subsequently became a superior method for the accurate γ(∞) determination. In this study, we validate our revised γ(∞)-calculation equation by measuring γ(∞) in an ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate system, in which 55 organic compounds covering a wide range of functional groups were used as probe solutes and their γ(∞) values in the ionic liquid were determined at 40.0, 50.0, and 60.0 °C. Experimental error analysis shows that our revised equation remarkably reduces the error compared to the common γ(∞)-calculation equation. Our data is consistent with previously reported values obtained via other techniques, which further proves the credibility of our revised equation. The accurately determined γ(∞) values can be directly used to calculate the partial molar excess enthalpy, selectivity, and capacity, which will benefit for the rapid screening of solvents (especially ionic liquids) in separation approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Determination of Sugars in Factory Products by Gas Chromatography Using Open Tubular Columns

Glucose, fructose, sucrose and kestose in a variety of factory products were determined .as trimethylsilyl derivatives by gas chromatography on open tubular columns. The advantages of using these columns are discussed.

متن کامل

Measurements of activity coefficients at infinite dilution of organic solutes and water on polar imidazolium-based ionic liquids

The activity coefficients at infinite dilution, c13, of 55 organic solutes and water in three ionic liquids with the common cation 1-butyl-3-methylimidazolium and the polar anions Cl , [CH3SO3] and [(CH3)2PO4] , were determined by (gas + liquid) chromatography at four temperatures in the range (358.15 to 388.15) K for alcohols and water, and T = (398.15 to 428.15) K for the other organic solute...

متن کامل

A study of the thermodynamic properties of poly [2-(3-mesityl-3-methylcyclobutyl)-2-hydroxyethyl methacrylate] at infinite dilution using inverse gas chromatography

Some thermodynamic quantities were obtained for the interactions of poly [2-(3-mesityl-3-methylcyclobutyl)2-hydroxyethyl methacrylate] with alcohols, ketones, acetates, aromatics and alkanes by inverse gas chromatography in the temperature range 160-200◦C. The specific retention volumes, V ◦ g , weight fraction activity coefficients of solute probes at infinite dilution, Ω1 , Flory-Huggins ther...

متن کامل

Solubility of Organics in Water and Silicon Oil: A Comparative Study

The aim of this study was to compare the solubility of selected volatile organic compounds in water and silicon oil using the simple static headspace method. The experimental design allowed equilibrium achievement within 30 – 60 minutes. Infinite dilution activity coefficients and Henry’s law constants for various organics representing esters, ketones, alkanes, aromatics, cycloalkanes and amine...

متن کامل

The Hildebrand Solubility Parameters of Ionic Liquids—Part 2

The Hildebrand solubility parameters have been calculated for eight ionic liquids. Retention data from the inverse gas chromatography measurements of the activity coefficients at infinite dilution were used for the calculation. From the solubility parameters, the enthalpies of vaporization of ionic liquids were estimated. Results are compared with solubility parameters estimated by different me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 21  شماره 

صفحات  -

تاریخ انتشار 2012