Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.

نویسندگان

  • J G Whayne
  • S Nath
  • D E Haines
چکیده

BACKGROUND Radiofrequency (RF) catheter ablation lesion size has been limited by the small volume of tissue directly heated by the RF electrode. Microwave (MW) energy has been proposed as an alternative energy source to generate larger lesions because of its increased volume of direct tissue heating. To further characterize MW ablation of myocardium, we studied the temperature-versus-distance profiles during MW ablation in an in vitro model of perfused and superfused porcine right ventricular free wall. METHODS AND RESULTS Radial tissue temperatures in 19 isolated porcine right ventricles were measured and recorded with four fluoroptic thermometry probes placed within the myocardium at 2.5-mm radial increments from the catheter. The MW antenna catheters used were monopolar and helical-coil antennas resonating at 915 and 2450 MHz. Durations of energy delivery for a 915-MHz MW monopolar antenna (60 to 600 seconds) and a 4-mm-tip RF electrode (60 and 300 seconds) were varied to compare time courses of lesion formation. For each lesion, the temperature at the lesion border zone (the isotherm of irreversible tissue injury) was determined. Similar lesion size and temperature profiles were observed for 915- versus 2450-MHz MW antennas and monopolar versus helical-coil MW antennas. Lesion depth for the 915-MHz monopolar antenna increased monoexponentially with a half-time of 170 seconds. The isotherms for all MW antenna designs were not significantly different. The mean isotherm of irreversible tissue injury for MW lesions was not significantly different from the mean isotherm for RF lesions (54.4 degrees C versus 53.6 degrees C, respectively). CONCLUSIONS Microwave ablation has the potential to directly heat a greater volume of tissue than RF ablation but only with efficient MW antennas. The primary mechanism of tissue injury for both MW and RF ablation appears to be thermal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microwave Tumor Ablation of Vertebral Bone Metastasis: A Case Report

Introduction: Thermal ablation by microwave (MWA) has proven efficacy in treatment of primary and metastatic cancers. Soft tissue tumors could be ablated completely using MWA. However, bony tissue metastasis particularly spinal vertebral metastasis ablation has not reported yet. Case presentation: A 50 year old male patient with primary diagnosed colon cancer undergone surgical resection of ...

متن کامل

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

Investigation on the Changes in Color Parameters and Turbidity of Cornelian Cherry (cornus mass L) Produced by Microwave and Conventional Heating

Background and Objectives: Red colored fruits such as cornelian cherry (Cornus mas L) are recognized as being healthy. The color of these fruits is an important sensory property in assessment of product quality therefore, minimizing the loss of color in the process is very important. Materials and Methods: In this study, comparison of the color, turbidity, degradation rate of anthocyanin, an...

متن کامل

Evaluation of Temperature Rise and Thermal Lesion Dimensions in Liver Laser Interstitial Thermotherapy

Introduction:  Laser  interstitial  thermotherapy  (LITT)  is  an  internal  ablation  therapy  method  consisting of a percutaneous or intraoperative insertion of laser fibers directly into the liver tumor with  maximum diameter of 5 cm. In this treatment method, there isn’t any general information about the  relationship  between  increasing  the  exposure  power,  coagulation  and  carboniza...

متن کامل

Experimental study on the effectiveness and safety of radiofrequency catheter ablation with the cooled ablation system.

Experimental in vitro and in vivo studies were performed to assess the effectiveness and safety of the cooled-tip catheter and the Cooled Ablation System, which enables the creation of deeper and wider burn lesions in the myocardial tissue using radiofrequency current. This system was confirmed to consistently create large burns by cooling the catheter tip with circulating water within the cath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 5  شماره 

صفحات  -

تاریخ انتشار 1994