Ultrasound gel minimizes third body debris with partial hardware removal in joint arthroplasty
نویسندگان
چکیده
Hundreds of thousands of revision surgeries for hip, knee, and shoulder joint arthroplasties are now performed worldwide annually. Partial removal of hardware during some types of revision surgeries may create significant amounts of third body metal, polymer, or bone cement debris. Retained debris may lead to a variety of negative health effects including damage to the joint replacement. We describe a novel technique for the better containment and easier removal of third body debris during partial hardware removal. We demonstrate hardware removal on a hip joint model in the presence and absence of water-soluble gel to depict the reduction in metal debris volume and area of spread.
منابع مشابه
Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملReverse Total Shoulder Arthroplasty for the Treatment Of Synovial Chondromatosis: A Case Report and Review of the Literature
Synovial chondromatosis affecting the glenohumeral joint is rare. Treatment primarily consists of arthroscopic loose body removal and synovectomy. Shoulder arthroplasty has been mentioned in the literature as a treatment option for patients with coexisting arthritis, although the results have been underreported. The case of an 84-year-old man with long standing synovial chondromatosis of the sh...
متن کاملTotal Knee Arthroplasty in Patients with Retention of Prior Hardware Material: What is the Outcome?
Background: There is an information gap in literature regarding postoperative outcome of total knee arthroplasty (TKA)in patients with hardware in-situ from the previous knee surgery. The present study aims to evaluate impact of retainedhardware on short-term outcome of TKA patients.Methods: Perioperative radiographs of patients who had undergone TKA between 2007 and 2012 were reviewedand patie...
متن کاملColoarticular fistula: A rare complication of revision total hip arthroplasty
Fistula formation between bowel and total hip arthroplasty or revision arthroplasty hardware is rare. We present a case of a 78-year-old woman with protrusio of left hip arthroplasty and acetabular reconstruction hardware that caused direct perforation of the sigmoid colon and fistula formation between the sigmoid colon and the left hip joint. The patient underwent several joint debridements, s...
متن کاملOutcome Assessment after Aptis Distal Radioulnar Joint (DRUJ) Implant Arthroplasty
Background: Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ) such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna. The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthro...
متن کامل