Sex differences in the significance of isolated reactive treponemal chemiluminescence immunoassay results.

نویسندگان

  • Rohan I Bopage
  • Ute Vollmer-Conna
  • Antonia W Shand
  • Jeffrey John Post
چکیده

OBJECTIVES The significance of sera with isolated reactive treponemal chemiluminescence immunoassay (IRTCIA) results is unclear. Women have this phenotype more commonly than men. Most cohorts examining this phenotype have included predominantly men and have demonstrated evidence of past or subsequently confirmed syphilis infection in a significant proportion of cases. We hypothesised that a proportion of sera with IRTCIA results would be positive on immunoblot testing and that sera from women with IRTCIA would have different results in immunoblot testing than men. METHODS IRTCIA sera from a tertiary referral serology laboratory serving multiple clinical sites were analysed with a syphilis line immunoblot assay (LIA) and analysed by sex. Logistic regression was undertaken to assess factors associated with LIA status. Medical record review and descriptive analysis of a separate cohort of women with the IRTCIA phenotype from a single campus was also undertaken. RESULTS Overall, 19/63 (30.1%) subjects with the IRTCIA phenotype were positive in the LIA, including 13 men and 6 women. Women were significantly less likely to have definitive results (positive or negative) than men (p=0.015). Pregnant women were less likely than non-pregnant women to have a negative LIA result (OR 0.57; p=0.03). Record review of 22 different women with IRTCIA reactivity showed that 2/22 (9.1%) had HIV and previous syphilis infection, 15/22 (68.2%) were pregnant and 3 (13.6%) had autoimmune disease. CONCLUSIONS A significant proportion of sera with IRTCIA results on serological tests are reactive on LIA testing and some may not be false positive results. The interpretation of IRTCIA results should be undertaken in conjunction with an assessment of factors such as sex, pregnancy, a history of syphilis and other STIs and syphilis risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of reverse sequence screening for syphilis.

Syphilis, which is caused by Treponema pallidum, is a chronic bacterial infection that remains a public health concern worldwide. Serologic testing is the method most often used, as the bacterium cannot be cultured. Syphilis serological tests are divided into nontreponemal and treponemal tests, and neither is sufficient alone for diagnosis, as each type of test has limitations, including the po...

متن کامل

A comparison of the analytical level of agreement of nine treponemal assays for syphilis and possible implications for screening algorithms

OBJECTIVE The serological diagnosis of syphilis requires the detection of two distinct antibodies, the non-treponemal and trepomenal. Center for Disease Control and Prevention (CDC) recommends screening first with a non-treponemal test such as (Rapid Plasma Reagin/Venereal Disease Research Laboratory), and then confirming those results with one of the several treponemal tests (Fluorescent Trepo...

متن کامل

Evaluation of the Vitros Syphilis TPA chemiluminescence immunoassay as a first-line method for reverse syphilis screening.

We report here the results of the diagnostic performances of Vitros Syphilis TPA (a chemiluminescence treponemal assay) compared with those of two treponemal enzyme immunoassays and of traditional versus reverse syphilis algorithms. Ease of use, automation, and high throughput make the Vitros Syphilis TPA assay a good choice for syphilis screening in high-volume laboratories.

متن کامل

Evaluation of a new chemiluminescence immunoassay for diagnosis of syphilis

OBJECTIVE To assess the sensitivity, specificity, and feasibility of a new chemiluminescence immunoassay (CLIA) in the diagnosis of syphilis. METHODS At first, a retrospective study was conducted, using 135 documented cases of syphilis and 30 potentially interfering samples and 80 normal sera. A prospective study was also performed by testing 2, 071 unselected samples for routine screening fo...

متن کامل

Discordant Syphilis Immunoassays in Pregnancy: Perinatal Outcomes and Implications for Clinical Management.

BACKGROUND The reverse sequence algorithm is often used for prenatal syphilis screening by high-volume laboratories, beginning with a treponemal test such as the chemiluminescence immunoassay (CIA), followed by testing of CIA-positive (CIA(+)) specimens with the rapid plasma reagin test (RPR). The clinical significance of discordant serology (CIA(+)/RPR(-)) for maternal and neonatal outcomes is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sexually transmitted infections

دوره   شماره 

صفحات  -

تاریخ انتشار 2013