Immunoprecipitation method for CK-MB analysis re-evaluated: influence of CK-BB and macro-CK on blank activities.
نویسندگان
چکیده
We evaluated the analytical performance of the immunoprecipitation technique for quantification of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB, focusing on specimens with increased blank activities. The samples we studied had blank values that were equal to or greater than either 15 U/L or the uncorrected CK-MB value. Of 134 specimens selected, 16 and 21 contained macro CK type 1 and CK-BB, respectively. All samples containing macro CK type 1 gave negative CK-MB values, even though four contained significant quantities of CK-MB. Correcting the blank value for the fluid displacement of the second antibody suspension eliminated all but three of the negative results. However, 45 specimens, negative for CK-MB by electrophoresis, gave CK-MB values ranging from 1 to 21 U/L. Furthermore, 11 of the specimens containing macro-CK type 1 were in this group. Thus, the presence of macro-CK type 1 definitely interferes with the immunoprecipitation technique. Our results indicate the need to re-evaluate the diagnostic accuracy of the immunoprecipitation technique, especially when the un-adjusted blank activities are increased.
منابع مشابه
Macro-creatine kinase co-migrating with CK-MB on electrophoresis.
Certain types ofmacro-CK, type 1, have been reported to cause false increases in CK-MB by co-migration on electrophoresis (1-3). I report two such cases in which the macroCK was an IgA with anti-CK-BB specificity. According to methods proposed by Medeiros et al. (1), immunoprecipitation and subsequent analysis by elecrophoresis was used to separate interfering macre-CK from CK-MB. CK electropho...
متن کاملCreatine kinase activities in sera of cirrhotics.
Sir, Creatine Kinase (CK) E.C. 2.7.3.2. is separable into three different isoenzymes by a number of methods. Each isoenzyme is a dimer composed of two subunits (Bor M) each having a relative molecular mass of 40,000. These isoenzymes are widely distributed in tissues, CK-MM and CK-MB are found mainly in the skeletal and heart muscles and CK-BB in G.l. tract and the brain with small amounts also...
متن کاملFalsely negative laboratory diagnosis for myocardial infarction owing to the concurrent presence of macro creatine kinase and macro lactate dehydrogenase.
Macro creatine kinase (CK, EC 2.7.3.2) and macro lactate dehydrogenase (LD, EC 1.1.1.27) were both present in the serum of a 70-year-old woman with myocardial infarction. This interfered with the interpretation of the CK and LD isoenzyme analyses. Gel filtration and immunoprecipitation showed that the macro CK consisted of IgG and CK and the macro LD of IgG and LD. The IgG in this patient bound...
متن کاملClinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.
We examined the clinical and analytical performance of two immunoassays (Becton Dickinson CK-MB; Ciba-Corning Magic Lite CK-MB) in which monoclonal anti-CK-MB antibodies are used for directly measuring creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum, and also one electrophoretic method (Ciba-Corning). Within- and between-assay precision for both immunoassays was good at the upper ref...
متن کاملImmunochemiluminometric assay of creatine kinase MB with a monoclonal antibody to the MB isoenzyme.
Previous two-site immunometric assays for creatine kinase (CK; EC 2.7.3.2) MB isoenzyme have been based on formation of a "sandwich" complex involving CK-MB and antibodies that recognize the CK-MM and the CK-BB isoenzymes. Single-incubation model assays of CK-MB with these antibodies were susceptible to interferences by CK-MM and CK-BB. We produced two anti-CK-MB monoclonal antibodies and studi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 34 3 شماره
صفحات -
تاریخ انتشار 1988