Randomized comparison between polymer-free versus polymer-based paclitaxel-eluting stent: two-year final clinical results.
نویسندگان
چکیده
BACKGROUND Most drug-eluting stents currently in use are coated with a polymer carrying the drug that is released for several weeks. However, a durable polymer may provoke hypersensitive reaction, delayed artery healing, and eventually stent thrombosis. The aim of this study was to investigate the safety and efficacy of a polymer-free paclitaxel-eluting stent (PF-PES) versus a polymer-based PES (PB-PES). METHODS AND RESULTS Eligible patients undergoing percutaneous coronary intervention were randomized 1:1 to receive either PF-PES or PB-PES. The primary end point was late loss at 9 months. Intravascular ultrasound analysis at 9 months and final 2-year clinical follow-up were also performed. From October 2007 to April 2009, 164 patients were enrolled and randomized into 2 groups (PF-PES: n = 84; PB-PES: n = 80). Mean in-stent lumen loss was 0.90 ± 0.59 mm for PF-PES and 0.49 ± 0.52 mm for PB-PES (P < 0.001). Mean neointimal area by intravascular ultrasound was higher in PF-PES than in PB-PES (1.42 ± 1.09 versus 0.51 ± 0.61 mm(2); P < 0.001). At 2 years, a composite end point of all-cause death, any myocardial infarction, and target vessel revascularization occurred in 36.9% for PF-PES and 16.3% for PB-PES (P = 0.004), mainly driven by a higher rate of target vessel revascularization (PF-PES: 35.7%; PB-PES: 13.8%; P = 0.001). One late stent thrombosis was observed in PF-PES. CONCLUSIONS Compared with PB-PES, PF-PES was associated with increased neointimal proliferation and subsequent clinical restenosis. Polymer plays an essential role in the performance of drug-eluting stents. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01375855.
منابع مشابه
Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.
INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...
متن کاملOne-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...
متن کاملOne-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent in patients with diabetes mellitus.
Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...
متن کاملRandomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: the LIPSIA Yukon trial.
OBJECTIVES The objective of the study was to assess noninferiority of the polymer-free sirolimus-eluting Yukon Choice stent (Translumina GmbH, Hechingen, Germany) compared with the polymer-based Taxus Liberté stent (Boston Scientific, Natick, Massachusetts) with regard to the primary endpoint, in-stent late lumen loss, at 9 months in patients with diabetes mellitus. BACKGROUND The Yukon Choic...
متن کاملOne-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial.
BACKGROUND The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. METHODS AND RESULTS In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2014