A micellar electrokinetic chromatography method for the determination of sumatriptan succinate in pharmaceutical formulations was developed. The effects of several factors such as pH, surfactant and buffer concentration, applied voltage, capillary temperature, and injection time were investigated. Separation took about 5 min using phenobarbital as internal standard. The separation was carried out in reversed polarity mode at 20 °C, 26 kV and using hydrodynamic injection for 10s. Separation was achieved using a bare fused-silica capillary 50 μm×40 cm and background electrolyte of 25 mM sodium dihydrogen phosphate-adjusted with concentrated phosphoric acid to pH 2.2, containing 125 mM sodium dodecyl sulfate and detection was at 226 nm. The method was validated with respect to linearity, limits of detection and quantification, accuracy, precision and selectivity. The calibration curve was linear over the range of 100-2000 μg mL(-1). The relative standard deviations of intra-day and inter-day precision for migration time, peak area, corrected peak area, ratio of corrected peak area and ratio of peak area were less than 0.68, 3.48, 3.28, 2.97 and 2.83% and 2.01, 5.50, 4.46, 4.92 and 4.07%, respectively. The proposed method was successfully applied to the determinations of the analyte in tablet. Forced degradation studies were conducted by introducing a sample of sumatriptan succinate standard solution to different forced degradation conditions using neutral (water), basic (0.1 M NaOH), acidic (0.1 M HCl), oxidative (10% H(2)O(2)) and photolytic (exposure to UV light at 254 nm for 2 h). It is concluded that the stability-indicating method for sumatriptan succinate can be used for the analysis of the drug in various samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling The Capacity Factor of Analytes in Micellar Electrokinetic Chromatography Using Computational Descriptors

       A multiple linear regression model is proposed to calculate capacity factor of  analytes using structural features computed using HyperChem software. The  chemical descriptors of analytes were computed using HyperChem software and  regressed against the experimental capacity factors of analytes collected from the  literature. The absolute average percentage deviation (AARD) and individua...

متن کامل

Simultaneous determination of insulin and its analogues in pharmaceutical formulations by micellar electrokinetic chromatography.

A simple and efficient MEKC method was developed to simultaneously determine human insulin, its five analogues, the main degradation products and the excipients usually present in injection formulations. A very fast method with a total analysis time of 3 min was then successfully validated for the analysis of human insulin and the quality control of commercial formulations was carried out.

متن کامل

Freeze-dried k-carrageenan/chitosan polyelectrolyte complex-based insert: a novel intranasal delivery system for sumatriptan succinate

Intranasal route, ensuring suitable bioavailability of medicines under circumvention of the gastrointestinal degradation and hepatic first-pass elimination, has been a popular choice for drug delivery. Among nasal dosage forms, mucoadhesive solid inserts have been shown to resist mucociliary clearance and provide a prolonged nasal residence time. Hence, the purpose of this study was the prepara...

متن کامل

Freeze-dried k-carrageenan/chitosan polyelectrolyte complex-based insert: a novel intranasal delivery system for sumatriptan succinate

Intranasal route, ensuring suitable bioavailability of medicines under circumvention of the gastrointestinal degradation and hepatic first-pass elimination, has been a popular choice for drug delivery. Among nasal dosage forms, mucoadhesive solid inserts have been shown to resist mucociliary clearance and provide a prolonged nasal residence time. Hence, the purpose of this study was the prepara...

متن کامل

Principles of micellar electrokinetic capillary chromatography applied in pharmaceutical analysis.

Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2011