A method for stabilizing a lingual fixed retainer in place prior to bonding.
نویسندگان
چکیده
AIM The objective of this article is to present a simple technique for stabilizing a lingual fixed retainer wire in place with good adaptation to the teeth surfaces and checking for occlusal interferences prior to the bonding procedure. BACKGROUND Bonding of an upper or lower fixed lingual retainer using stainless steel wires of different sizes and shapes is a common orthodontic procedure. The retainer can be constructed in a dental laboratory, made at chair side, or it can be purchased in prefabricated form. All three ways of creating a fixed retainer are acceptable. However, the method of holding the retainer wire in place adjacent to the lingual surfaces of the teeth before proceeding with the bonding process remains a problem for some practitioners. REPORT The lingual fixed retainer was fabricated using three pieces of .010" steel ligature wire which were twisted into a single strand wire. Another four to five 0.010" pieces of steel ligature wires were twisted in the same way to serve as an anchor wire from the labial side of the teeth. The retainer wire was bonded using the foible composite. SUMMARY The technique presented here for stabilizing the retainer wire prior to bonding provides good stabilization, adaptation, and proper positioning of the retainer wire while eliminating contamination of etched surfaces which might arise during wire positioning before bonding. This technique also allows the clinician the opportunity to check the occlusion and adjust the retainer wire to avoid occlusal interference prior to bonding maxillary retainers. This same clinical strategy can be used to stabilize wires for splinting periodontally affected teeth and traumatized teeth.
منابع مشابه
Time-saving fixed lingual retainer using DuraLay resin transfer.
There is general agreement on the necessity of fixed lingual retainers to prevent relapse in many patients after active orthodontic treatment. Several methods for delivering fixed lingual retainers have been introduced. However, bonding a lingual retainer is still challenging because it requires long working time and has a risk of contamination from saliva and moisture, which can cause bonding ...
متن کاملWire jigs for stabilizing lingual retainers.
T simple stabilizing jigs for bonded lingual retainer wires are easily fabricated from materials in the office, using the following procedure: 1. Bend a circular retentive tag into one end of an .031" stainless steel wire segment.* 2. Double-wind the wire 6-8mm from the tag to form a helix with an internal diameter of 3mm (A). 3. Bend the other end of the wire 90°, leaving a space of about 2mm ...
متن کاملBond strength of two techniques for bonding lingual orthodontic retainer
AIM: The aim of this study was to compare the shear bond strength of two techniques for bonding lingual orthodontic retainer; the chairside modified bonding technique introduced by Al-Emran and Hashim, and the chairside manual bonding technique currently used in orthodontic practice. MATERIALS AND METHODS: Sixty-four extracted cariesfree premolars were divided into two equal groups. Group A rep...
متن کاملA prospective clinical evaluation of mandibular lingual retainer survival.
Bonded retainers are considered reliable, independent of patient co-operation, and highly efficient. However, most studies regarding the survival of retainers are retrospective. The aims of this investigation were to prospectively evaluate the failure rate of bonded lingual retainers, the influence of direct or indirect bonding procedures on survival, and to determine the distribution of failur...
متن کاملAssessing the feasibility of yttria-stabilized zirconia in novel designs as mandibular anterior fixed lingual retention after orthodontic treatment.
INTRODUCTION The purpose of this study is to explore the feasibility of yttria-stabilized zirconia (Y-TZP) in fixed lingual retention as an alternative to stainless steel. METHODS Exploratory Y-TZP specimens were milled to establish design parameters. Next, the specimens were milled according to ASTM standard C1161-13 and subjected to 4-point flexural tests to determine material properties. F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 8 7 شماره
صفحات -
تاریخ انتشار 2007