A simple tissue model for practicing ultrasound guided vascular cannulation.

نویسندگان

  • H Baddoo
  • R Djagbletey
  • C Owoo
چکیده

INTRODUCTION The use of ultrasound in anaesthetic practice continues to be more established and the use of ultrasound guidance in establishing vascular access is recommended by various groups. We have developed a tissue model for the practice and skills development in ultrasound vascular access. METHOD The tissue model consist of a piece of "pork belly", a longitudinal shaped balloon inserted between two muscle layers at a chosen depth of the tissue model (mimics a blood vessel), a bag of intravenous fluid (e.g. Ringer's Lactate) together with a giving set and a short piece of extension tubing connected to a three-way tap used to expel air from the system. One end of the balloon is tied to the giving set with the intravenous fluid. The other end is tied to the short tubing with the three-way tap. RESULTS Ultrasound images of the fluid filled balloon mimic a blood vessel. It is possible under ultrasound guidance to puncture the balloon several times (>10times) and still be able to distend the balloon with fluid. INTERPRETATION Ultrasound guided techniques require practice to improve hand-eye coordination. The "pork belly" tissue model allows multiple needle puncture without losing its functional integrity. CONCLUSION We believe the "pork belly" tissue model adds to the range of models that can be used to practice ultrasound guided vascular access. The components required for this model are readily available locally and affordable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-guided cannulation of hemodialysis access

Because hemodialysis therapy cannot be performed without the cannulation of a vascular access, establishing a well-functioning vascular access is crucial. Recently, the number of patients with difficult arteriovenous (AV) fistula cannulation has increased due to changes in the epidemiology of the dialysis population. To address this issue, indications for real-time ultrasound-guided techniques ...

متن کامل

Ultrasound guidance for central vascular access in the pediatric emergency department.

Central vascular access is sometimes required for hemodynamic monitoring and infusion of fluids and medications in the pediatric emergency department. In many cases, it is attempted after failed peripheral venous and intraosseous access. Some evidence exists demonstrating benefits of ultrasound (US)-guided central vascular cannulation in adults in emergency departments. With appropriate educati...

متن کامل

Optimization of Cannula Visibility during Ultrasound-Guided Subclavian Vein Catheterization, via a Longitudinal Approach, by Implementing Echogenic Technology

Objective. One limitation of ultrasound-guided vascular access is the technical challenge of visualizing the cannula during insertion into the vessel. We hypothesized that the use of an echogenic vascular cannula (EC) would improve visualization when compared with a nonechogenic vascular cannula (NEC) during real-time ultrasound-guided subclavian vein (SCV) cannulation in the ICU. Material and ...

متن کامل

A novel approach for US-guided central venous cannulation in phantom models: the oblique technique

Objective Ultrasound (US) guided central vascular access is an indispensable skill for physicians. Recently, a novel approach to vascular cannulation, the oblique technique, has been described. This technique combines the advantages of the traditional (short axis, SA, and long axis, LA) approaches, while purportedly avoiding their pitfalls. This claim has not been well studied. We aimed to comp...

متن کامل

The oblique approach for US-guided peripheral venous cannulation in phantom models

Objective Ultrasound (US) guided peripheral vascular access is a valuable skill for physicians. A novel approach to vascular cannulation called the oblique technique has been described, which purports to eliminate the disadvantages of the traditional techniques (short axis, SA; and long axis, LA) while preserving their advantages. This technique has not been well studied. We aimed to compare th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ghana medical journal

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2014