Thyroid Ultrasound-Guided Fine-Needle Aspiration: The Positive Influence of On-Site Adequacy Assessment and Number of Needle Passes on Diagnostic Cytology Rate.
نویسندگان
چکیده
OBJECTIVE Nondiagnostic cytology is the most important limitation of thyroid ultrasound-guided fine-needle aspiration (US-FNA). This study aimed to identify factors associated with the adequacy rate of thyroid US-FNA. STUDY DESIGN Consecutive thyroid US-FNAs (2006-2013) were retrospectively included. Attending radiologists, radiology fellows and radiology residents performed US-FNA, usually involving 2-3 needle passes. In more recent years, rapid on-site adequacy assessment (ROSAA) was performed to ensure specimen adequacy. US characteristics, procedural variations and cytology results were extracted from US and pathology reports and statistically evaluated. RESULTS Diagnostic cytology was obtained in 64.6% of 1,381 thyroid US-FNAs. Factors associated with nondiagnostic cytology were ROSAA (74.6% diagnostic cytology, OR 0.55, 95% CI 0.42-0.71), ≥3 clinic visits for US-FNA of the same thyroid nodule (54.7%, OR 1.56, 95% CI 1.16-2.10) and increased intranodular vascularization (51.8%, OR 1.73, 95% CI 1.17-2.57). With ROSAA, an increasing number of needle passes demonstrated improving adequacy rates. The adequacy rate was not operator-dependent. CONCLUSION This study demonstrates that ROSAA improves the adequacy rate of thyroid US-FNA. Without ROSAA, we recommend performing at least 3 needle passes. Less diagnostic cytology is obtained from nodules with increased intranodular vascularization or from those undergoing US-FNA ≥3 times.
منابع مشابه
Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study
Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...
متن کاملFine Needle Aspiration Cytology versus Fine Needle Capillary Sampling in Cytological Diagnosis of Thyroid Lesions
Background and Objectives: Fine needle aspiration cytology (FNAC) is an established out- patient procedure used in primary diagnosis of palpable thyroid lesions. A modified technique fine needle capillary sampling (FNCS) obviates the need of suction, is less painful, patient friendly and reported to overcome the problem of inadequate and bloody specimens. The aim of our study was to compare the...
متن کاملComparison of Cytologic Reports of Fine-Needle Aspiration of Thyroid Nodules with Pathologic Results of Thyroid Surgery
Background and Objective: Thyroid nodules are among the most common clinical problems and the application of an inexpensive and accurate diagnostic method prevents performing inessential surgeries. In this regard, the aim of this study was to compare the cytologic report of fine-needle aspiration (FNA) of thyroid nodules with the results of thyroid surgery. Materials and Methods: In this cross...
متن کاملRole of Fine Needle Aspiration Cytology in Diagnosis of Solitary Thyroid Nodules
Introduction: This study was conducted at the Department of ear, nose, throat, head and neck surgery, Post Graduate Medical Institute Lady Reading Hospital Peshawar. The duration of the study was one year from June 17, 2009 to June 16, 2010. The sample size was 82 patients with solitary thyroid nodule, fulfilling the inclusion criteria. After taking detailed history, thorough examination, rele...
متن کاملSenthil P et al ACCURACY OF ULTRASOUND GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN THE EVALUATION OF THYROID NODULES
Background: Thyroid nodules are a common problem which requires an accurate cytological diagnosis for proper management. An essential investigation modality is fine needle aspiration cytology (FNAC) with a sensitivity ranging between 80-90%. Recommendations vary regarding the use of ultrasound in improving the accuracy of free hand fine needle aspiration biopsy. Objective: The aim of our study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta cytologica
دوره 60 1 شماره
صفحات -
تاریخ انتشار 2016