A New Algorithm for the Generation of Reference Voltages of a DVR Using the Method of Instantaneous Symmetrical Components

نویسنده

  • Avinash Joshi
چکیده

Author Affiliation: Department of Electrical Engineering, Indian Institute of Technology, Kanpur, India. Abstract: This letter presents a new method for the generation of reference voltage for a dynamic voltage restorer (DVR). These voltages, when injected in series with a distribution feeder by a voltage source inverter, can tightly regulate the voltage at the load terminal against imbalance or harmonics in the source side. It is stipulated that the DVR does not supply any real power in the steady state. The reference voltage generation scheme is validated through digital computer simulation studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory

Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

"SRF theory revisited" to control self supported dynamic voltage restorer (DVR) for unbalanced and nonlinear loads

In this paper a fuzzy controller based DVR is proposed for the protection of the sensitive unbalanced nonlinear loads from sag/swell, distortion, and unbalance in supply voltage is achieved. A simple generalized algorithm based on basic synchronous reference frame theory has been developed for the generation of instantaneous reference compensating voltages for controlling a DVR. This novel algo...

متن کامل

A SAIWD-Based Approach for Simultaneous Reconfiguration and Optimal Siting and Sizing of Wind Turbines and DVR units in Distribution Systems

In this paper, a combination of simulated annealing (SA) and intelligent water drops (IWD) algorithm is used to solve the nonlinear/complex problem of simultaneous reconfiguration with optimal allocation (size and location) of wind turbine (WT) as a distributed generation (DG) and dynamic voltage restorer (DVR) as a distributed flexible AC transmission systems (DFACT) unit in a distribution sys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016