Appropriate electrode placement site for electric pulp testing of anterior teeth in Nigerian adults: a clinical study.
نویسندگان
چکیده
Electric pulp testing is one of the pulp vitality tests which aid dentists in diagnosis of the pulp status. This test is technique sensitive and hence may elicit false responses. There are some concerns regarding the optimal placement of the probe tip. The threshold value (the lowest electric current at which sensation is perceived) is reached when an adequate number of nerve fibers are stimulated, so the sensation would be greatest where the density of neural distribution is the highest. The purpose of this study was to identify the optimum site for electrode placement in anterior teeth of adults, the threshold values of these teeth using an electric pulp test, and to determine the influence of sex, age, and arch on the outcome. The optimum electrode placement sites and threshold values varied with type of tooth and arch. The maxillary teeth, canines, male gender and increasing age required higher electric current to evoke a sensation, while incisal edges required lower current to evoke a sensation.
منابع مشابه
بررسی اثر محل قرارگیری الکترود پالپ تستر در پاسخ دندانهای قدامی فک بالا
Background and Aims: Electric pulp testing is used for diagnosis of the pulp status. This test is technique sensitive and hence may elicit positive or negative false response in case of inaccurate use. The optimal site for placement of the probe tip has not been determined. The aim of this study was to evaluate the effect of pulp tester probe placement site on the response of maxillary teeth.Ma...
متن کاملA determination of the sensitivity of the dental pulp of primary maxillary anterior teeth to electrical stimuli in children with unilateral and bilateral clefts.
A study was conducted to determine differences in pulpal sensitivity of the maxillary primary anterior teeth in groups of children with unilateral clefts of the lip, alveolar process and palate, bilateral clefts of the lip process, and children without clefts. Thirty-nine children between the ages of 4 and 5 years with a total of 216 maxillary primary anterior teeth were tested using a pulp tes...
متن کاملElectric pulp testing: a review.
Electric pulp testing (EPT) has been available for more than a century and used in dental practices worldwide. This article provides an overview of this diagnostic aid. The PubMed database from 1953 was used initially; the reference list for pulp testing featured 1071 articles, and for EPT identified 121 papers. A forward search was undertaken on these articles and using selected author names. ...
متن کاملبررسی اثر سن بیمار بر پاسخ دندان به پالپ تستر الکتریکی
Background and Aims: Electric pulp tester is a valuable instrument to examine tooth’s pulp vitality. There is no agreement about the response of immature teeth to electric pulp tester and the reason is expressed as the failure of nerve fibers’ development. The aim of this study was to investigate the effect of patient’s age on the tooth response to electric pulp tester. Materials and Method...
متن کاملInterradicular Space in the Anterior Mandible on CBCT Scans of an Iranian Population
Abstract Background and Aim: This study aimed to assess the bone thickness at the interradicular spaces in the anterior mandible on cone-beam computed tomography (CBCT) scans of patients to find appropriate sites for mini-implant and miniscrew placement. Materials and Methods: This analytical cross-sectional study was conducted on 161 CBCT scans of patients (98 females and 63 male...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of oral science
دوره 52 2 شماره
صفحات -
تاریخ انتشار 2010