Application of constrained optimization to radiotherapy planning.

نویسندگان

  • O A Sauer
  • D M Shepard
  • T R Mackie
چکیده

Essential for the calculation of photon fluence distributions for intensity modulated radiotherapy (IMRT) is the use of a suitable objective function. The objective function should reflect the clinical aims of tumor control and low side effect probability. Individual radiobiological parameters for patient organs are not yet available with sufficient accuracy. Some of the major drawbacks of some current optimization methods include an inability to converge to a solution for arbitrary input parameters, and/or a need for intensive user input in order to guide the optimization. In this work, a constrained optimization method was implemented and tested. It is closely related to the demanded clinical aims, avoiding the drawbacks mentioned above. In a prototype treatment planning system for IMRT, tumor control was guaranteed by setting a lower boundary for target dose. The aim of low complication is fulfilled by minimizing the dose to organs at risk. If only one type of tissue is involved, there is no absolute need for radiobiological parameters. For different organs, threshold dose, relative seriality of the organs or an upper dose limit could be set. All parameters, however, were optional, and could be omitted. Dose-volume constraints were not used, avoiding the possibility of local minima in the objective function. The approach was benchmarked through the simulation of both a head and neck and a lung case. A cylinder phantom with precalculated dose distributions of individual pencil beams was used. The dose to regions at risk could be significantly reduced using at least seven ports of beam incidence. Increasing the number of ports beyond seven produced only minor further gain. The relative seriality of organs was modeled through the use of an added exponent to the dose. This approach however increased calculation time significantly. The alternative of setting an upper limit is much faster and allows direct control of the maximum dose. Constrained optimization guarantees high tumor control probability, it is computationally more efficient than adding penalty terms to the objective function, and the input parameters are dose limits known in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved genetic algorithm for multidimensional optimization of precedence-constrained production planning and scheduling

Integration of production planning and scheduling is a class of problems commonly found in manufacturing industry. This class of problems associated with precedence constraint has been previously modeled and optimized by the authors, in which, it requires a multidimensional optimization at the same time: what to make, how many to make, where to make and the order to make. It is a combinatorial,...

متن کامل

Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...

متن کامل

Solving Security Constrained Unit Commitment by Particle Swarm Optimization

The issue of unit commitment is one of the most important economic plans in power system. In modern and traditional power systems, in addition to being economical of the planning, the issue of security in unit operation is also of great importance. Hence power system operation confronts units’ participation and input considering network security constrains. The issue of units’ participation is ...

متن کامل

Sparse Solution for the Intensity-Modulated Radiotherapy Problem Using Conic Programming

We address the problem of planning an effective IMRT (Intensity Modulated Radiotherapy) treatment for cancer. IMRT is a modern method of radiotherapy. It irradiates cancerous tissues by administering lethal dose of radiation to those cells, while sparing the healthy tissues. This method’s greatest advantage is the large degree of freedom which it allows the treatment planning, but it is also it...

متن کامل

Trajectory Optimization of Cable Parallel Manipulators in Point-to-Point Motion

Planning robot trajectory is a complex task that plays a significant role in design and application of robots in task space. The problem is formulated as a trajectory optimization problem which is fundamentally a constrained nonlinear optimization problem. Open-loop optimal control method is proposed as an approach for trajectory optimization of cable parallel manipulator for a given two-end-po...

متن کامل

Chance Constrained Planning and Scheduling under Uncertainty using Robust Optimization Approximation

Robust optimization can provide safe and tractable analytical approximation for the chance constrained optimization problem. In this work, we studied the application of robust optimization approximation in solving chance constrained planning and scheduling problem under uncertainty. Four different robust optimization approximation methods for improving the quality of robust solution were invest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 26 11  شماره 

صفحات  -

تاریخ انتشار 1999