Comparison of Kneelax and KT-1000 knee ligament arthrometers.
نویسندگان
چکیده
Two commercially available knee ligament arthrometers (KT-1000 MEDmetric Corporation, San Diego, California and Kneelax MR Systems, Haarlem, The Netherlands) were used to measure anterior tibial translation. In this study 91 subjects with no history of knee pathology were tested using both devices. Both normal knees were tested and comparison of recorded anterior translation (millimeters) was performed. Absolute numbers at forces of 67N, 89N, 134N, and manual maximum displacements were recorded. Side-to-side differences were calculated and data were compared. There was a significant difference found between the absolute values of each device. The KT-1000 was found to record greater values in millimeters of translation. Although the absolute values were significantly different, the side-to-side differences were not significantly different between devices.
منابع مشابه
Bench testing of a knee joint arthrometer.
The KT1000 and KT2000 knee joint arthrometers (MEDmetric Corp, San Diego, California) have been shown to overestimate the measurement of knee joint sagittal laxity. The purpose of this study was to investigate the accuracy of the KT arthrometers as measures of anterior and posterior linear displacement. The anterior and posterior linear displacements of 3 KT arthrometers (2 KT1000 arthrometers ...
متن کاملReview article: Validity of the KT-1000 knee ligament arthrometer.
The KT-1000 knee arthrometer (KT-1000) is an objective instrument to measure anterior tibial motion relative to the femur for anterior cruciate ligament (ACL) reconstruction. Four studies between 1950 and 2007 regarding validity of the KT-1000 were identified using a Medline search. One had interpretable information on sensitivities, specificities, and predictive values to validate the instrume...
متن کاملMeasurement of anterior-posterior knee laxity: a comparison of three techniques.
Several non-invasive techniques have been developed to assess anterior-posterior (A-P) laxity of the knee, however, their accuracy remains unclear. Roentgen Stereophotogrammetry Analysis (RSA) is a three-dimensional motion analysis method that has been shown to be an accurate tool for evaluating joint kinematics. Thus. RSA provides a means that can be used to evaluate other less invasive techni...
متن کاملOutcomes of ACL Reconstruction With Fixed Versus Variable Loop Button Fixation.
Suspensory femoral fixation of anterior cruciate ligament (ACL) grafts with fixed loop button and variable loop button devices has gained popularity for ACL reconstruction. This study examined these 2 methods of fixation to determine their effect on graft laxity and patient-reported outcome scores. A database search was performed to identify patients who had undergone ACL reconstruction with ei...
متن کاملIntratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee.
We measured tibial translation in the knees of 22 subjects with posterior cruciate ligament tears or reconstructions by using the KT-1000 arthrometer. To assess the reliability of the device, two testers made measurements. One tester was a novice and the second tester had substantial clinical experience with the KT-1000 arthrometer. The quadriceps neutral angle was found for the uninvolved knee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of knee surgery
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2012