A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions

نویسندگان

  • Osama Khattak
  • Ebadullah Raidullah
  • Maria L. Francis
چکیده

OBJECTIVES This study aimed to evaluate the accuracy of Root ZX in determining working length in presence of normal saline, 0.2% chlorhexidine and 2.5% of sodium hypochlorite. MATERIAL AND METHODS Sixty extracted, single rooted, single canal human teeth were used. Teeth were decoronated at CEJ and actual canal length determined. Then working length measurements were obtained with Root ZX in presence of normal saline 0.9%, 0.2% chlorhexidine and 2.5% NaOCl. The working length obtained with Root ZX were compared with actual canal length and subjected to statistical analysis. RESULTS No statistical significant difference was found between actual canal length and Root ZX measurements in presence of normal saline and 0.2% chlorhexidine. Highly statistical difference was found between actual canal length and Root ZX measurements in presence of 2.5% of NaOCl, however all the measurements were within the clinically acceptable range of ±0.5mm. CONCLUSION The accuracy of EL measurement of Root ZX within±0.5 mm of AL was consistently high in the presence of 0.2% chlorhexidine, normal saline and 2.5% sodium hypochlorite. CLINICAL SIGNIFICANCE This study signifies the efficacy of ROOT ZX (Third generation apex locator) as a dependable aid in endodontic working length. Key words:Electronic apex locator, working length, root ZX accuracy, intracanal irrigating solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants

BACKGROUND Cleaning and shaping of root canal system requires various irrigating solutions. The question is whether the presence of irrigation solution alters working length determination using apex locators. The purpose of this study was to compare the accuracy of Root ZX and i-Root apex locator for determining working length in the presence of different irrigating solution. MATERIALS AND ME...

متن کامل

ارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول کانال دندانهای شیری در شرایط In vivo

Background and Aim: Radiography is the most commonly used technique in root canal length determination, but its application in pedodontics is difficult due to many problems such as radiation hazards, superimposition of permanent teeth buds and uncooperative children. The aim of this study was to investigate the accuracy of an electronic apex locator (Dentaport ZX) in measuring the root canal le...

متن کامل

The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...

متن کامل

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

Accuracy of three electronic apex locators in the presence of different irrigating solutions.

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014