Harmonic elimination of cascaded H-bridge multilevel inverter based active power filter controlled by intelligent techniques

نویسندگان

  • G. Nageswara Rao
  • Sangameswara Raju
  • K. Chandra Sekhar
چکیده

In this paper, an Adaptive Neuro Fuzzy Interference System (ANFIS) is proposed for eliminating voltage harmonics present in the multilevel inverter. It is achieved by reducing the THD present in the multilevel inverter output voltage. Here, the voltage variation of the multilevel inverter is determined from the actual load voltage and the reference voltage. The voltage variation at different time interval has been applied to the ANFIS. According to the voltage variations, the switching angles can be generated from the interference system. These switching angles can make the multilevel inverter output voltage with reduced THD. The proposed technique is implemented in the MATLAB/simulink working platform. The effectiveness of the proposed method is evaluated by the multilevel inverter output voltage without controller and with Neuro Fuzzy Controller (NFC). 2014 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Compensation of Electrical Power Systems Using Multilevel Voltage Source Inverter

A New Static Var Generator (SVG), using cascaded full-bridge inverters (FBI) with binary output levels and the parallel connections of two cascaded inverters by means of current sharing reactor in each phases is introduced. The new M-level inverter, where M is 2n+2 - 3, consists of only 2n single-phase full bridges for each phases. The proposed technique not only increases the current capacity ...

متن کامل

Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-P...

متن کامل

استفاده از اینورتر چندسطحی با کنترل‌کننده غیرخطی مستقیم برای اتصال مزرعه خورشیدی به شبکه

The solar photovoltaic (PV) farm delivers its harvested DC energy to the AC grid via power electronic interfaces. With insolation as well as ambient temperature variations, these power electronic converters should regulate operating point at optimal point to extracting maximum power from PV cells. In this paper, a direct nonlinear control method is developed for cascaded H-bridge multilevel inv...

متن کامل

Harmonic Compensation and Load Balancing Using Cascaded H- bridge Multilevel Inverter in High Voltage Systems

This paper presents detailed modeling and simulation of a compensator for Load balancing and harmonics Compensation based on a five-level cascaded H-bridge multilevel voltage source inverter. This type of compensator, which is installed in parallel with the load, is usually referred to as the shunt active power filters (APF). Nowadays use of high voltage non-linear loads are widely used in indu...

متن کامل

New Hybrid Cascaded Multilevel Inverter

This paper proposes a single-phase five-level inverter with a modified pulse width-modulated (PWM)control scheme. The modified pulse width-modulation technique is developed to reduce switching loss.Also, the proposed multilevel inverter can reduce the requirement of power switches compared to aconventional cascaded multilevel inverter. The modes of operation, control signals, and operatingprinc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016