Is valve choice a significant determinant of paravalular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis.

نویسندگان

  • Katie E O'Sullivan
  • Aideen Gough
  • Ricardo Segurado
  • Mitchel Barry
  • Declan Sugrue
  • John Hurley
چکیده

OBJECTIVES Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations. METHODS A systematic review and meta-analysis of the current literature to identify PVR rate in patients with MCV and ES valves was performed. We also sought to examine other factors predisposing to PVR. RESULTS A total of 5910 patients were identified from 9 studies. PVR rates for MCV and ES were analysed. MCV was associated with a higher PVR rate of 15.75% [95% confidence interval (CI) 12.48-19.32] compared with ES 3.93% [95% CI 1.05-8.38]. We separately reviewed predisposing factors associated with PVR. A formal comparison of the MCV and ES valve leakage rates by mixed-effects meta-regression with a fixed-effect moderator variable for valve type (MCV or ES) suggested a statistically significant difference in leakage rate between the two valve types (P = 0.0002). CONCLUSIONS Unfavourable anatomical and pathological factors as well as valve choice have an impact on rates of PVR. Additionally, certain anatomical features dictate valve choice. A direct comparison of all the predisposing factors at this time is not possible and will require prospective multivariate analysis. There is, however, a significant difference in the PVR rates between valves based on the published observational data available to date. The ES valve associated with a lower incidence of PVR overall; therefore, we conclude that valve choice is indeed a significant determinant of PVR post-TAVI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is valve choice the most important determinant of paravalvular leak following TAVI?

Background Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ in a variety of ways. The primary objective of this study was to perform a systematic review and metaanalysis of studies identifying PVR in patients post TAVI to firstly identify the overall incidence and s...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Transcatheter Aortic Valve Implantation With or Without Percutaneous Coronary Artery Revascularization Strategy: A Systematic Review and Meta‐Analysis

BACKGROUND Recent recommendations suggest that in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation and coexistent significant coronary artery disease, the latter should be treated before the index procedure; however, the evidence basis for such an approach remains limited. We performed a systematic review and meta-analysis to study the clinical outcomes of...

متن کامل

Sex-related differences in outcomes after transcatheter aortic valve implantation: a systematic review and meta-analysis.

BACKGROUND There were considerable discrepancies with regard to sex-related differences in complications and prognosis after transcatheter aortic valve implantation. METHODS AND RESULTS The Cochrane library and PubMed online databases were searched. Articles reporting sex-specific post-transcatheter aortic valve implantation complications and mortality were identified. Two authors selected st...

متن کامل

Approaches for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Introduction: Retrograde transfemoral and antegrade transapical approaches are mostly used for transcatheter aortic valve replacement. This meta-analysis is designed to assess the performance of the transfemoral and transapical approach. Methods: A systematic search was conducted using MEDLINE, PubMed, EMBASE, Current

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 2014