Sources of error in measuring cerebrospinal fluid formation by ventriculocisternal perfusion.
نویسندگان
چکیده
Ventriculocisternal perfusion is regarded as a precise method of measuring the rate of formation of cerebrospinal fluid (CSF) but it possesses inherent potential sources of error. Using the technique to measure CSF formation rate in the rhesus monkey, we have observed rate changes when none were expected. Most puzzling has been the steady decline of CSF formation rate at 4 percent each hour during the final five hours of a seven hour perfusion although variables known to affect CSF formation remained stable. In addition, alterations in rate caused by artefacts were observed in experiments in which craniospinal blood volume was changed by sudden changes of either PCO2 or central venous pressure. Mobilisation or sequestration of incompletely equilibrated CSF is believed responsible. In other experiments, a small increase of intracranial pressure produced by increasing outflow resistance was quickly followed by an apparent reduction of CSF formation. We have concluded that to assess accurately the effect a variable has on the rate of CSF formation, one must control perfusion time and craniospinal blood volume as well as intracranial pressure.
منابع مشابه
Potential error in ventriculocisternal perfusion method for determination of cerebrospinal fluid formation rate in cats.
The cerebrospinal fluid (CSF) formation rate (Vf) has been extensively studied by the ventriculocisternal perfusion, a method still regarded as the most precise one. This method as well as the equation for the calculation of the CSF formation rate (Vf) was established by Heisey et al on indicator dilution in perfusate. They assumed that the dilution of the indicator substance in perfusion is a ...
متن کاملStudy of central regulation of intraocular pressure using ventriculocisternal perfusion.
The ability of hypoosmotic solution, prostaglandin E1 (PGE1) and clonidine to influence intraocular pressure (IOP) by a central mechanism was studied using the technique of ventriculocisternal perfusion in conscious rabbits. IOP remained unchanged during the perfusion of 150 mOsm artificial cerebrospinal fluid. IOP rapidly increased by 15 mmHg during the perfusion of PGE1 at the dose of 1 or 3 ...
متن کاملFluid perfusion as a method of cerebrospinal fluid formation rate--critical appraisal.
The aim of the study was to evaluate whether or not cerebrospinal fluid formation rate (Vf) calculated according to the equation of Heisey et al., truly show the produced cerebrospinal fluid. For this reason Vf was simulated (40.6 microL/min) by an infusion pump in a plastic cylinder and the evaluation was done by comparing the results obtained between the calculated Vf and the simulated one. I...
متن کاملCerebrospinal fluid formation and absorption in dehydrated sheep.
Cerebrospinal fluid (CSF) plays an important role in the brain's adaptive response to acute osmotic disturbances. In the present experiments, the effect of 48-h dehydration on CSF formation and absorption rates was studied in conscious adult sheep. Animals had cannulas chronically implanted into the lateral cerebral ventricles and cisterna magna to enable the ventriculocisternal perfusion. A 48...
متن کاملEvaluation of ventriculo-cisternal perfusion model as a method to study cerebrospinal fluid formation.
AIM To evaluate ventriculo-cisternal perfusion as a method for measuring cerebrospinal fluid formation rate, calculated by means of the Heisey et al equation. Method. All experiments were carried out on anesthetized domestic cats fixed in the sphinx position in a stereotaxic frame. Ventriculo-cisternal perfusion was used at an intracranial pressure of -10 cm H2O at different perfusion rates (32...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 40 7 شماره
صفحات -
تاریخ انتشار 1977