Arterial imaging with a new forward-viewing intravascular ultrasound catheter, II. Three-dimensional reconstruction and display of data.

نویسندگان

  • K H Ng
  • J L Evans
  • M J Vonesh
  • S N Meyers
  • T A Mills
  • B J Kane
  • W N Aldrich
  • Y T Jang
  • P G Yock
  • M D Rold
چکیده

BACKGROUND Current intravascular ultrasound (IVUS) catheters provide transverse imaging at the level of the ultrasound transducer. This limits imaging to large-diameter segments without critical atherosclerotic narrowings. We have developed a prototype 20-MHz forward-viewing IVUS catheter that provides two-dimensional sector imaging distal to the catheter tip. A present limitation of this technique is that the catheter must be manually rotated to obtain multiple longitudinal views required to integrate the segment into a three-dimensional matrix. To overcome this, we have developed an algorithm that reconstructs these multiple two-dimensional forward-viewing IVUS images into a three-dimensional matrix for more complete depiction of the segment distal to the ultrasound catheter. This algorithm allows display and multidimensional slicing of the three-dimensional reconstruction. METHODS AND RESULTS. To test our algorithms, five arterial segments (three canine aortas, two human femoral arteries) were evaluated in vitro. In each segment, 36 forward-viewing longitudinal slices were collected, digitized, processed, and reoriented to produce a three-dimensional reconstruction (3DR) matrix. The matrix data were sliced into parallel transverse sections and compared with morphometric interpretation of histological sections (Histo). As a result, image data could be reconstructed for a distance of 2.0 cm ahead of the catheter. 3DR easily demonstrated wall and luminal morphology and provided transverse IVUS images comparable to the histological specimens. A good correlation was noted between Histo- and 3DR-determined luminal diameters (LD) and luminal areas: 3DR LD = 1.4 Histo LD-0.4, r = .86; 3DR LD = 0.7 +/- 0.20 cm (mean +/- SD); and Histo LD = 0.7 +/- 0.13 cm. CONCLUSIONS These preliminary data demonstrate the feasibility of 3DR of forward-viewing IVUS data. This method allows rapid, detailed analysis of diseased arterial segments previously unavailable with standard IVUS and may permit better targeting of interventional techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial imaging with a new forward-viewing intravascular ultrasound catheter, I. Initial studies.

BACKGROUND Intravascular ultrasound (IVUS) of arteries is limited by the inability of current instruments to visualize beyond the catheter tip. We have developed a prototype 4-mm-diameter forward-viewing IVUS catheter (Cardiovascular Imaging Systems, Sunnyvale, Calif) that has the ability to provide B-mode cross-sectional ultrasound data for a distance of up to 2 cm distal to the catheter tip. ...

متن کامل

Three - dimensional Reconstruction of Intracoronary Ultrasound

Although intracoronary ultrasonography allows detailed tomographic imaging of the arterial wall, it fails to provide data on the structural architecture and longitudinal extent of arterial disease. This information is essential for decision making during therapeutic interventions. Three-dimensional reconstruction techniques offer visualization of the complex longitudinal architecture of atheros...

متن کامل

1044 Three - dimensional Reconstruction of Intracoronary Ultrasound

Although intracoronary ultrasonography allows detailed tomographic imaging of the arterial wall, it fails to provide data on the structural architecture and longitudinal extent of arterial disease. This information is essential for decision making during therapeutic interventions. Three-dimensional reconstruction techniques offer visualization of the complex longitudinal architecture of atheros...

متن کامل

Intravascular ultrasound. Research technique or clinical tool?

I ntravascular ultrasound is a new technique that allows intraluminal catheter-based vascular imaging. Technological advances in miniaturization have produced 4F to 8F catheters that can be safely maneuvered within coronary and peripheral arteries.1,2 Images obtained provide accurate measurements of lumen area as well as high-resolution images of arterial wall components.3,4 Histopathological s...

متن کامل

Intraluminal fluorescence spectroscopy catheter with ultrasound guidance.

We demonstrate the feasibility of a time-resolved fluorescence spectroscopy (TRFS) technique for intraluminal investigation of arterial vessel composition under intravascular ultrasound (IVUS) guidance. A prototype 1.8-mm (5.4 Fr) catheter combining a side-viewing optical fiber (SVOF) and an IVUS catheter was constructed and tested with in vitro vessel phantoms. The prototype catheter can locat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 1994