3D high-spatial-resolution cerebral MR venography at 3T: a contrast-dose-reduction study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The effect of various contrast-dose regimens for cerebral MR venography (MRV) has not been previously evaluated at 3T, to our knowledge. Our purpose was to evaluate and compare the diagnostic image quality resulting from half-versus-full-dose contrast regimens for high-spatial-resolution 3D cerebral MRV at 3T. MATERIALS AND METHODS Forty consecutive patients with known or suggested cerebrovascular disease underwent 3D high-spatial-resolution (0.7 x 0.6 x 0.9 mm(3)) cerebral contrast-enhanced MRV (CE-MRV) at 3T, by using an identical acquisition protocol. Patients were assigned to 1 of 2 groups: 1) full-dose (approximately 0.1 mmol/kg), and 2) half-dose (approximately 0.05 mmol/kg). Two readers evaluated the resulting images for overall image quality, venous structure definition, and arterial contamination. Signal intensity-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were evaluated in 8 consistent sites. Statistical analysis was performed by using Mann-Whitney U, Wilcoxon signed rank, and t tests and a kappa coefficient. RESULTS Both readers scored venous-structure definition as excellent or sufficient for diagnosis in approximately 90% of segments for the full-dose group (kappa = 0.87) and in approximately 80% of segments for the half-dose group (kappa = 0.85). Delineation grades were significantly lower for small venous segments, including the middle cerebral, septal, superior cerebellar, inferior vermian, posterior tonsillar, and thalamostriate veins in the half-dose group (P < .01). No significant difference existed for arterial contamination grades between the 2 groups (P > .05). SNR and CNR values were lower in the half-dose group (P < .01). CONCLUSIONS At 3T, high-spatial-resolution cerebral MRV can be performed with contrast doses as low as 7.5 mL, without compromising image quality as compared with full-dose protocols, except in the smallest veins, and without compromise of acquisition speed or spatial resolution.
منابع مشابه
3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging.
The diagnostic image quality of contrast-enhanced (CE) 3D MR venography (MRV) was prospectively compared with that of 2D time-of-flight (TOF) MRV and contrast-enhanced 3D magnetization-prepared rapid acquisition of gradient echo (MPRAGE) sequences for the visualization of the intracranial venous system at 3T in 22 patients. CE MRV provides high-quality images and was shown to be superior to TOF...
متن کاملUltra high resolution venography using T2* weighted imaging at 7T MRI
Throughout the last two decades, MRI has been ameliorated by a dramatic increase in the field strength; from 0.015 to 7 Tesla (T) MR systems. Ultrahigh-field MR system (beyond 3T) has great potential to produce newly improved imaging capabilities for both clinical diagnosis and basic science research. The primary purpose of venography was the description of cerebral veins, but it has also been ...
متن کاملImprovement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising
The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and h...
متن کاملHigh-Quality Venography from Multi-echo MR Dataset using T2* Relaxation Model
Introduction MR venography (MRv) has an important role in diagnosis of venous diseases. Unlike x-ray or CT venography, MRv produces venographic images without any ionizing radiation. Obtaining venographic image with low noise and high contrast is clinically important for diagnosis of vascular diseases based on MRv. It has been reported that the best venography can be acquired at TE=28ms for vei...
متن کاملMR ANGIOGRAPHY, FLOW, AND ENDOTHELIAL FUNCTION High-field MR angiography on an in vitro stenosis model determination of the spatial resolution on 1.5 and 3T in correlation to flow velocity and contrast medium concentration
Since the first description of coronary magnetic angiography (MRA) in the early of 1990, this method seems to be shaped us a promising noninvasive modality to view the coronary arteries. Since several years dedicated high-field MR systems up to 4T are available for human use. The aim of the study was the evaluation of an in vitro vessel model with defined stenoses on 1.5T and 3T. For imaging at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2009