A comparative clinical study of the failure rate of orthodontic brackets bonded with two adhesive systems: conventional and self-etching primer (SEP).

نویسندگان

  • Gladys Cristina Dominguez
  • André Tortamano
  • Luiz Vicente de Moura Lopes
  • Priscilla Campanatti Chibebe Catharino
  • Camillo Morea
چکیده

OBJECTIVE This study compared the clinical performance of orthodontic brackets bonded with Transbond adhesive paste after two primer systems: a two-stage conventional system (acid etching + Transbond XT adhesive primer) and a single-stage self-etching primer (SEP) (Transbond Plus). METHODS The sample comprised 480 metal brackets bonded to the teeth of 24 consecutive patients treated for 36 to 48 months. A split-mouth design was used for bonding, and both systems were used in each patient. Bracket failure rates for each system were analyzed; and failure causes as reported by the patients and the quadrant of teeth for which brackets failed were recorded. RESULTS The conventional system group had a failure rate of 5.41%, whereas the rate for SEP was 4.58%. In this group, there were 5 failures (38.4%) in the right maxillary quadrant, 2 (15.4%) in the left maxillary quadrant, 4 (30.8%) in the right mandibular quadrant, and 2 (15.4%) in the left mandibular quadrant. In the SEP group, there were 4 (36.4%) failures in the right maxillary quadrant, 1 (9%) in the left maxillary quadrant, 3 (27.3%) in the right mandibular quadrant, and 3 (27.3%) in the left mandibular quadrant. Results of descriptive statistical analysis and odds ratio did not show any significant differences between rates (p = 0.67). CONCLUSIONS The clinical efficiency of SEP was similar to that of the conventional system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets

Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...

متن کامل

Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

BACKGROUND Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. MA...

متن کامل

Effect of enamel protective agents on shear bond strength of orthodontic brackets

BACKGROUND This paper aimed to study the effect of two enamel protective agents on the shear bond strength (SBS) of orthodontic brackets bonded with conventional and self-etching primer (SEP) adhesive systems. METHODS The two protective agents used were resin infiltrate (ICON) and Clinpro; the two adhesive systems used were self-etching primer system (Transbond Plus Self Etching Primer + Tran...

متن کامل

Effectiveness of Self-Etching Primer Versus Conventional Etch and Bond Technique in Fixed Orthodontic Treatment (Keberkesanan Teknik Primer Pengasidan Sendiri Berbanding Teknik Pengasidan serta Pengikatan Konvensional pada Rawatan Ortodontik Tetap)

A good adhesive is an important factor to consider in orthodontic bonding. Frequent bracket failure prolongs treatment duration and causes inconvenience to patient and operator. This study aimed to compare the effectiveness of two bonding agents, i.e. the self etching primer (SEP) and the conventional etch and bond (CEB) by monitoring the incidence, time and sites of bracket failure. Eighty ort...

متن کامل

Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling

Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental press journal of orthodontics

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2013