Risk of coronary artery compression among patients referred for transcatheter pulmonary valve implantation: a multicenter experience.

نویسندگان

  • Brian H Morray
  • Doff B McElhinney
  • John P Cheatham
  • Evan M Zahn
  • Darren P Berman
  • Patrick M Sullivan
  • James E Lock
  • Thomas K Jones
چکیده

BACKGROUND The Melody transcatheter pulmonary valve (TPV) was approved for implantation in obstructed right ventricular outflow tract conduits in 2010 after a multicenter trial demonstrating improvements in conduit obstruction, regurgitation, and right ventricular pressure. A recognized risk and contraindication to TPV implantation is the demonstration of coronary artery (CA) compression during balloon angioplasty or stent placement in the overlying conduit. This study is the first to characterize the risk of CA compression in this population. METHODS AND RESULTS From 2007 to 2012, 404 patients underwent 407 catheterizations for potential TPV implantation (median age, 18 years) at 4 centers. Three hundred forty-three patients (85%) underwent valve implantation. Twenty-one patients (5%) had evidence of CA compression with simultaneous right ventricular outflow tract angioplasty and CA angiography. Sixty-eight patients (17%) had abnormal CA anatomy. Fifteen of 21 (71%) patients with CA compression had abnormal CA anatomy. Eight patients with tetralogy of Fallot and 7 patients with transposition of the great arteries demonstrated compression. Of the 34 patients with tetralogy of Fallot and abnormal CA, 7 (21%) demonstrated CA compression. CONCLUSIONS CA compression following TPV implantation can be catastrophic. CA compression was observed in 5% of patients during test balloon angioplasty. No patients in this study developed clinically apparent CA compression after TPV implantation. CA compression was significantly associated with the presence of abnormal CA anatomy, especially in patients with tetralogy of Fallot or transposition of the great arteries. Preimplantation coronary angiography with simultaneous test angioplasty is an important step to evaluate for the presence of CA compression during TPV implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial.

BACKGROUND Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. METHODS AND RESULTS From January 2007 to August 2009, 136 patients (median age, 19 years) ...

متن کامل

Valvular Heart Disease Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

Background—Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results—From January 2007 to August 2009, 136 patients (median age, 19 years) un...

متن کامل

Left anterior descending coronary artery occlusion during transcatheter pulmonary valve implantation: successful rescue percutaneous revascularization.

A 34-year-old woman was referred for transcatheter pulmonary valve implantation. She had been exposed to radiotherapy for Hodgkin’s disease and underwent a Ross procedure 16 years before for post-endocarditis aortic regurgitation. Test-balloon angioplasty with a 22 20-mm Atlas balloon (Bard Peripheral Vascular, Tempe, Arizona) inflated to 14 atm, showed no coronary compression (Figure 1A, Onlin...

متن کامل

Implantation of transcatheter aortic valve prosthesis through the ascending aorta concomitant with coronary artery bypass grafting without cardiopulmonary bypass

INTRODUCTION The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. OBJECTIVE The aim of this study is to approach the implantation of transcatheter aortic valve throug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2013