Effect of heliox on end-tidal CO2 measurement in healthy adults.

نویسندگان

  • Jonathan B Waugh
  • Donna D Gardner
  • David L Vines
چکیده

BACKGROUND Therapeutic gases and other modalities delivered by inhalation may affect the accuracy of capnographic measurements in 2 ways. First is the specificity of the measurement of CO2 within the device, and second is the dilution effect of supplemental gases in the ambient air during CO2 sampling by the device. Our goal was to determine if variables such as inhaled gas composition, gas flows delivered via non-rebreather mask, and mouth open or closed affect measurements of end-tidal CO2 pressure (PETCO2) measured with the Capnostream 20 capnograph. METHODS We measured PETCO2 and breathing frequency by capnography in 20 adult normal subjects, with coaching to maintain respiratory frequency between 10 and 20 breaths/min. SpO2 was monitored to detect hypoxemia. A 6 min wash-out period occurred between each 6 min level of testing. RESULTS A mixed models analysis revealed that the mean ± SD PETCO2 for all subjects and flows while breathing heliox (37 ± 5 mm Hg) was not different (P = .50) from the value while breathing room air (36 ± 5 mm Hg). Repeated measurements with given subjects over 6 min periods of breathing spontaneously 0 L/min, with 10 L/min, and with 15 L/min of either air or heliox showed no difference in PETCO2 related to flow: P = .97 for 0 L/min vs 10 L/min, P = .87 for 0 L/min vs. 15 L/min. CONCLUSIONS In normal subjects, PETCO2 measurements with the Capnostream 20 were not affected by heliox or gas flow at 10 or 15 L/min through a non-rebreathing mask.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نیاز‌های توجهی کنترل الگوی تنفس و ارتباط آن با پیامد‌های متابولیکی تنفس در افراد سالم

Objective: Normal breathing is essential for adjustment of natural metabolism of human body. Therefore, the aim of this study was to evaluate the control of breathing pattern in normal subjects both at rest and during cognitive loading. Materials & Methods: In this quasi-experimental study, 24 healthy subjects (14 males, 10 females) were selected by simple and convenient sampling. Spirometry...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

تأثیر تهویه با حجم‌های جاری متفاوت و تهویه دقیقه‌ای ثابت بر روی دی‌اکسید کربن انتهای بازدمی

Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study  to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2  and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...

متن کامل

Heliox Allows for Lower Minute Volume Ventilation in an Animal Model of Ventilator-Induced Lung Injury

BACKGROUND Helium is a noble gas with a low density, allowing for lower driving pressures and increased carbon dioxide (CO2) diffusion. Since application of protective ventilation can be limited by the development of hypoxemia or acidosis, we hypothesized that therefore heliox facilitates ventilation in an animal model of ventilator-induced lung injury. METHODS Sprague-Dawley rats (N=8 per gr...

متن کامل

Heliox Improves Carbon Dioxide Removal during Lung Protective Mechanical Ventilation

Introduction. Helium is a noble gas with low density and increased carbon dioxide (CO2) diffusion capacity. This allows lower driving pressures in mechanical ventilation and increased CO2 diffusion. We hypothesized that heliox facilitates ventilation in patients during lung-protective mechanical ventilation using low tidal volumes. Methods. This is an observational cohort substudy of a single a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 11  شماره 

صفحات  -

تاریخ انتشار 2013