Assessment of Fibrinolysis in Sepsis Patients with Urokinase Modified Thromboelastography

نویسندگان

  • Mauro Panigada
  • Lucia Zacchetti
  • Camilla L’Acqua
  • Massimo Cressoni
  • Massimo Boscolo Anzoletti
  • Rossella Bader
  • Alessandro Protti
  • Dario Consonni
  • Armando D’Angelo
  • Luciano Gattinoni
  • A.B. Johan Groeneveld
چکیده

INTRODUCTION Impairment of fibrinolysis during sepsis is associated with worse outcome. Early identification of this condition could be of interest. The aim of this study was to evaluate whether a modified point-of-care viscoelastic hemostatic assay can detect sepsis-induced impairment of fibrinolysis and to correlate impaired fibrinolysis with morbidity and mortality. METHODS This single center observational prospective pilot study was performed in an adult Intensive Care Unit (ICU) of a tertiary academic hospital. Forty consecutive patients admitted to the ICU with severe sepsis or septic shock were included. Forty healthy individuals served as controls. We modified conventional kaolin activated thromboelastography (TEG) adding urokinase to improve assessment of fibrinolysis in real time (UK-TEG). TEG, UK-TEG, plasminogen activator inhibitor (PAI)-1, thrombin-activatable fibrinolysis inhibitor (TAFI), d-dimer, DIC scores and morbidity (rated with the SOFA score) were measured upon ICU admission. Logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (95% CIs) of mortality at ICU discharge. RESULTS UK-TEG revealed a greater impairment of fibrinolysis in sepsis patients compared to healthy individuals confirmed by PAI-1. TAFI was not different between sepsis patients and healthy individuals. 18/40 sepsis patients had fibrinolysis impaired according to UK-TEG and showed higher SOFA score (8 (6-13) vs 5 (4-7), p = 0.03), higher mortality (39% vs 5%, p = 0.01) and greater markers of cellular damage (lactate levels, LDH and bilirubin). Mortality at ICU discharge was predicted by the degree of fibrinolysis impairment measured by UK-TEG Ly30 (%) parameter (OR 0.95, 95% CI 0.93-0.98, p = 0.003). CONCLUSIONS Sepsis-induced impairment of fibrinolysis detected at UK-TEG was associated with increased markers of cellular damage, morbidity and mortality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapleural Fibrinolysis in Post-tubercular Loculated Pleural Effusions at a Tertiary-Care Respiratory Center: An Uncontrolled Blinded Before-After Intervention Study

Background: Tuberculous, parapneumonic and traumatic loculated pleural-effusions pose therapeutic challenges due to resultant pleural-thickening and compromised lung-function for life. Tuberculosis is widely prevalent in developing countries, necessitating appropriate, effective, and economical treatment for loculated pleural-effusion to reduce the burden and sequelae. <s...

متن کامل

Endogenous fibrinolytic potential in tissue-plasminogen activator-modified thromboelastography analysis is significantly decreased in dogs suffering from diseases predisposing to thrombosis.

BACKGROUND In people, studies have shown that resistance to fibrinolysis could be a contributing factor to thrombosis. Tissue-plasminogen-activated (t-PA) thromboelastography (TEG) has been used to evaluate endogenous fibrinolytic potential. In dogs, TEG has been used for the diagnosis of various hemostatic disorders, but studies evaluating fibrinolysis are limited. Investigations into the pote...

متن کامل

Molecular adsorbent recirculating system and hemostasis in patients at high risk of bleeding: an observational study

INTRODUCTION Liver failure is associated with reduced synthesis of clotting factors, consumptive coagulopathy, and platelet dysfunction. The aim of the study was to evaluate the effects of liver support using a molecular adsorbent recirculating system (MARS) on the coagulation system in patients at high risk of bleeding. METHODS We studied 61 MARS treatments in 33 patients with acute liver fa...

متن کامل

Soluble urokinase plasminogen activator receptor (suPAR) in the emergency department: An update

Background: The biomarker soluble urokinase plasminogen activator receptor (suPAR) is an indicator of inflammation which is increased in a variety of chronic and acute disease states. Its most promising application in the emergency setting is to aid in the prognostic stratification of patients by identifying those at high risk of deterioration. This is a narrative review of studies evaluating t...

متن کامل

Assessment of coagulation and fibrinolysis in pre-eclampsia.

A method is described for distinguishing coagulation from fibrinolysis by three estimates of fibrinogen. This "fibrinogen series" together with plasma antithrombin and urinary urokinase have been compared in pregnant patients with venous thrombosis and pre-eclampsia. Evidence is presented for active coagulation during deterioration of the pre-eclampsia state and for enhanced fibrinolysis during...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015