Prospective randomised study to evaluate effectiveness of distal embolic protection compared to abciximab administration in reduction of microembolic complications of primary coronary angioplasty.
نویسندگان
چکیده
BACKGROUND Myocardial reperfusion following primary percutaneous coronary intervention (pPCI) is limited due to, among other things, microembolic events. Abciximab and a mechanical system of distal protection both reduce their incidence during PCI. AIM Prospective, randomised study to compare effectiveness of abciximab and protection devices in reduction of microembolic complications during pPCI. METHODS One hundred and twenty consecutive patients with ST elevation acute myocardial infarction referred for pPCI after coronary angiography were randomly assigned to the following groups: Group A (n=63), treated with abciximab; and Group B (n=57), treated using the distal protection system. Primary endpoint was blood flow through the infarct-related artery (IRA) using TIMI grading after pPCI; secondary endpoints included myocardial perfusion assessment using myocardial blush grade (MBG), ST resolution and improvement of echocardiographic left ventricular ejection fraction (LVEF) after pPCI. RESULTS TIMI grade 3 flow after pPCI was obtained in 89% of patients in both groups, TIMI grade 2 flow in 5% (NS). Myocardial perfusion after pPCI assessed with MBG scored 3 in 66% of patients in group A and 62% of patients in group B (NS). ST resolution was present in 62% (26-84) in group A and 68% (41 - 86) in group B (NS). Logistic regression analysis showed no significant influence of selected variables on the primary endpoint. Analysis performed in the distal protection group revealed significant effects on the following factors on the final TIMI flow in IRA: presence of thrombus prior to pPCI (p=0.026), presence of residual thrombus after aspiration (p <0.001), and IRA diameter of > or =3.5 mm (p=0.01). Median LVEF in group A at sixth month of follow-up was 46% (44-50%), similar to group B - 46% (45-49%) (NS). CONCLUSIONS Use of the PercuSurge distal protection device during pPCI allows angiographic and electrocardiographic measures of reperfusion to be improved. It has a similar effect on left ventricular systolic function as administration of abciximab. The device seems to be useful in patients with culprit artery diameter of > or =3.0 mm, and optimally > or =3.5 mm and thrombus visible on angiography. Successful initial thrombectomy prior to deployment of stent seems particularly important when using the PercuSurge system.
منابع مشابه
ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملThe Effect of Primary Angioplasty and Drug Therapy in Elderly Patients with Acute Coronary Syndrome
Background & Aims: The aging of the population has caused an increase in the number of elderly people who receive treatment for cardiovascular disease. The prevalence of coronary artery disease is higher in the elderly, and on the other hand, complications after cardiac events are worse in the elderly. The most common cause of death in the elderly is cardiovascular disease. Rapid restoration of...
متن کاملLetter by Naggara et al regarding article, "Are distal protection devices 'protective' during carotid angioplasty and stenting?".
BACKGROUND AND PURPOSE To evaluate the periprocedural outcome after carotid artery stenting with embolic brain protection (EBP+) versus without embolic brain protection (EBP-). METHODS We retrospectively reviewed data from a prospective nonrandomized database of 357 patients who underwent carotid artery stenting in the neuroradiology division of our institution from 1999 to 2009. One hundred ...
متن کاملRandomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.
BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...
متن کاملAssociation between high sensitivity C-reactive protein (hs-CRP) levels and the risk of major adverse cardiovascular events (MACE) and/or microembolic signals after carotid angioplasty and stenting
Background: To evaluate the association between pre/post-procedural high sensitive C-reactive protein (hs-CRP) level and hs-CRP difference, and the risk of major adverse cardiovascular events (MACE) or new diffusion-weighted MRI lesions after carotid angioplasty and stenting (CAS). Methods: In this study, conducted in 2016 in Shiraz (Iran), patients who underwent diagnostic angiography and CAS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kardiologia polska
دوره 65 6 شماره
صفحات -
تاریخ انتشار 2007