Single stage insertion of the Molteno tube for glaucoma and modifications to reduce postoperative hypotony.

نویسندگان

  • J E Hoare Nairne
  • D Sherwood
  • J S Jacob
  • W J Rich
چکیده

Severe glaucoma was controlled in all 13 cases following insertion of a Molteno drain in a single stage procedure. One eye required a repeat operation. A modified technique to minimise early postoperative hypotony and prevent flat anterior chambers is described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supra-tenon capsule placement of original Molteno vs Molteno 3 tube implants in black patients with refractory glaucoma: a single-surgeon experience.

OBJECTIVE To evaluate the efficacy of supra-Tenon capsule placement of original Molteno vs Molteno 3 tube implants (Molteno Ophthalmic, Dunedin, New Zealand) in black patients with refractory glaucoma. METHODS A retrospective study comparing the efficacy of supra-Tenon capsule placement of the original Molteno tube implant (130-mm(2) plate size) with the newer Molteno 3 tube implant (175-mm(2...

متن کامل

Otago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.

OBJECTIVE To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma. METHODS A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant. RESULTS Success was defi...

متن کامل

EYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma

Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...

متن کامل

Surgical technique: complex glaucoma case requiring Molteno drainage tube extension

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had...

متن کامل

Molteno3: Design and clinical evaluation

We describe the Molteno3 glaucoma implant, its design principles and the differences and similarities with the current generation of Molteno implant. Clinical results from 37 Molteno3 implant procedures for primary open angle glaucoma are compared with a control group of 33 pressureridge single plate Molteno implants. The results obtained in cases of primary open angle glaucoma, neovascular gla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 72 11  شماره 

صفحات  -

تاریخ انتشار 1988