Effect of calibration method on distortion-product otoacoustic emission measurements at and around 4 kHz.
نویسندگان
چکیده
OBJECTIVES Distortion-product otoacoustic emissions (DPOAEs) collected after sound pressure level (SPL) calibration are susceptible to standing waves that affect measurements at the plane of the probe microphone due to overlap of incident and reflected waves. These standing-wave effects can be as large as 20 dB, and may affect frequencies both above and below 4 kHz. It has been shown that forward pressure level (FPL) calibration minimizes standing-wave effects by isolating the forward-propagating component of the stimulus. Yet, previous work has failed to demonstrate more than a small difference in test performance and behavioral-threshold prediction with DPOAEs after SPL and FPL calibration. One potential limitation in prior studies is that measurements were restricted to octave and interoctave frequencies; as a consequence, data were not necessarily collected at the standing-wave null frequency. In the present study, DPOAE responses were measured with f2 set to each participant's standing-wave frequency in an effort to increase the possibility that differences in test performance and threshold prediction would be observed for SPL and FPL calibration methods. DESIGN Data were collected from 42 normal-hearing participants and 93 participants with hearing loss. DPOAEs were measured with f2 set to 4 kHz and at each participant's notch frequency after SPL and FPL calibration. DPOAE input/output functions were obtained from -10 to 80 dB in 5 dB steps for each calibration/stimulus condition. Test performance was evaluated using clinical decision theory. Both area under receiver operating characteristic curves for all stimulus levels and cumulative distributions when L2 = 50 dB (a level at which the best performance was observed regardless of calibration method) were used to evaluate the accuracy with which auditory status was determined. A bootstrap procedure was used to evaluate the significance of the differences in test performance between SPL and FPL calibrations. DPOAE predictions of behavioral threshold were evaluated by correlating actual behavioral thresholds and predicted thresholds using a multiple linear regression model. RESULTS First, larger DPOAE levels were measured after SPL calibration than after FPL calibration, which demonstrated the expected impact of standing waves. Second, for both FPL and SPL calibration, test performance was best for moderate stimulus levels. Third, differences in test performance between calibration methods were evident at low- and high-stimulus levels. Fourth, there were small but statistically significant improvements in test performance after FPL calibration for clinically relevant conditions. Fifth, calibration method had no effect on threshold prediction. CONCLUSIONS Standing waves after SPL calibration have an impact on DPOAE levels. Although the effect of calibration method on test performance was small, test performance was better after FPL calibration than after SPL calibration. There was no effect of calibration method on predictions of behavioral threshold.
منابع مشابه
Influence of calibration method on distortion-product otoacoustic emission measurements: I. test performance.
OBJECTIVE Calibration errors in distortion-product otoacoustic emission (DPOAE) measurements because of standing waves cause unpredictable changes in stimulus and DPOAE response level. The purpose of this study was to assess the extent to which these errors affect DPOAE test performance. Standard calibration procedures use sound pressure level (SPL) to determine specified levels. Forward pressu...
متن کاملEvaluation of the effect of gemcitabine on cochlea by otoacoustic emission in experimental animal model.
OBJECTIVES In this study, we aimed to search whether gemcitabine - a commonly used antimetabolite type antineoplastic agent-has ototoxic effect. STUDY DESIGN AND SETTING An experimental animal research. SUBJECTS AND METHODS We evaluated the effect of gemcitabine on hearing through its possible effect on cochlea by using otoacoustic emission method on experimental rat model. For this purpose...
متن کاملCharacteristics of the 2f(1)-f(2) distortion product otoacoustic emission in a normal hearing population.
Distortion-product otoacoustic emission (DPOAE) fine structure and component characteristics are reported between 0.75 and 16 kHz in 356 clinically normal hearing human subjects ages 10 to 65 yr. Stimulus tones at 55/40, 65/55, and 75/75 dB SPL were delivered using custom designed drivers and a calibration method that compensated for the depth of insertion of the otoacoustic emission (OAE) prob...
متن کاملDistribution of standing-wave errors in real-ear sound-level measurements.
Standing waves can cause measurement errors when sound-pressure level (SPL) measurements are performed in a closed ear canal, e.g., during probe-microphone system calibration for distortion-product otoacoustic emission (DPOAE) testing. Alternative calibration methods, such as forward-pressure level (FPL), minimize the influence of standing waves by calculating the forward-going sound waves sepa...
متن کاملDo "optimal" conditions improve distortion product otoacoustic emission test performance?
OBJECTIVES To determine whether an "optimal" distortion product otoacoustic emission (DPOAE) protocol that (1) used optimal stimulus levels and primary-frequency ratios for each f2, (2) simultaneously measured 2f2 - f1 and 2f1 - f2 distortion products, (3) controlled source contribution, (4) implemented improved calibration techniques, (5) accounted for the influence of middle ear reflectance, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 34 6 شماره
صفحات -
تاریخ انتشار 2013