Dosimetric Performance of A-Si Electronic Portal Imaging Devices
نویسندگان
چکیده
The majority of EPID dosimetry literature discusses response linearity and the so-called image lag and ghosting effects despite the lack of a common definition of these quantities. However, the results of these studies are generally not consistent, and it is often difficult to compare the results from different studies. We present here a detailed study of the acquisition and readout characteristics of a-Si EPID and its dosimetric performance. EPID response was assessed over the range of 1 500 MU using different dose rates and integration times. In addition, a computer model was designed to simulate the EPID image formation with different dose, dose rate, and integration time combinations. All aspects of image processing and readout simulation were carried out using custom written MatLab codes. Two distinct signal profiles were observed depending on the delivered dose, dose rate and integration time combination. Total integrated signal (ST) is linear with the delivered dose. For dosimetry, image lag and ghosting effects mainly result in the residual signal (SR) that appears as delayed signal after the end of irradiation. At its maximum, SR is less than 2.5% of ST. The readout technique is such that it is impossible to measure SR accurately. SR is definable only when readout equilibrium occurs. Signal profiles provide a through and reliable description of the EPID response incorporating the dose, dose rate, integration time, and the residual signal. The definition of EPID signals based on this method shall provide an accurate universal EPID dosimetry framework.
منابع مشابه
A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملEvaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy
Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...
متن کاملEPID in vivo Dosimetry
Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...
متن کاملPortal imaging.
Portal imaging is the acquisition of images with a radiotherapy beam. Imaging theory suggests that the quality of portal images could be much higher if the efficiency of the imaging media in detecting radiation could be improved. Introduction of new media (films and electronic portal imaging devices) has confirmed this by markedly increasing the quality of portal images. Images from these devic...
متن کاملThe Influence of Acquisition Mode on the Dosimetric Performance of an Amorphous Silicon Electronic Portal Imaging Device
AIMS This study investigates the impact of cine acquisition mode on the dosimetric characteristics of a Varian aS500 amorphous silicon electronic portal imaging device (a-Si EPID). MATERIALS AND METHODS The performance of an a-Si EPID operated in cine mode was assessed and compared to its performance when operated in an integrated mode and dose measurements using an ionization chamber. This s...
متن کاملMonte Carlo simulation of the transit dosimetric response of an a-Si electronic portal imaging device
Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) are x-ray detectors frequently used in radiotherapy imaging and dosimetry applications. EPIDs employ a copper plate and gadolinium oxysulfide phosphor screen with an array of a-Si photodiodes to indirectly detect incident radiation. In this study, a previously developed Monte Carlo (MC) model of an aSi EPID has been extended for...
متن کامل