An analytical investigation has been conducted on the performance of an adsorption chiller driven by solar collector panel for the climatic condition of Dhaka. A set of mathematical model and simulation technique are exploited to investigate the system performances of solar driven basic adsorption chiller with silica gel-water as adsorbent/adsorbate pair. For base run condition, at least 13 collectors (each of area 2.415 2 m ) are essential to achieve the required heat source temperature (around 85° C) to provide 10 kW cooling capacity. It is seen that the chiller provide 10kw cooling capacity at noon, while, the system provides solar COP around 0.35. It is also observed that the collector size can be reduced by optimizing cycle time and chilled water outlet temperature can be controlled by setting an appropriate chilled water flow rate.
منابع مشابه
Information Services Paradigm for Small and Medium Enterprises Based on Cloud Computing Heyong Wang A Novel Task Partitioning Method for Multi-core Processor Based-on Cohesion and Coupling
An analytical investigation has been conducted on the performance of an adsorption chiller driven by solar collector panel for the climatic condition of Dhaka. A set of mathematical model and simulation technique are exploited to investigate the system performances of solar driven basic adsorption chiller with silica gel-water as adsorbent/adsorbate pair. For base run condition, at least 13 col...
متن کاملStudy of the performance of a solar adsorption cooling system
This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...
متن کاملPerformance of Building Energy Efficiency by Orientation with Regression: a Case of Semi Desert in Iran
In this research multiple-regression analysis with stepwise selection method was employed for investigating the effectof vertical building envelopes solar radiation (Evr) on cooling energy consumption (E cooling) in residential sector.The high capacity of solar energy in semi-arid climate (Shiraz) can provide a part of buildings required energy. Dependson house orientations in two directions of...
متن کاملSimulation of a New Hybrid Solar and Organic Cycle as a Combined Cooling, Heat and Power (CCHP) Unit in Off Design Condition
In this paper, using parabolic mirrors, a solar field was designed, which was related to a storage tank for a residential complex in the city of Tafresh located in the center of Iran. The design was performed for the existing oils: VP1, THERMINOL 66, THERMINOL 59. Finally, considering an organic cycle with R123 as working fluid and assuming a minimum length required for oil flow rate to reach a...
متن کاملMeasuring the Thermal Comfort Function in the Combination of Solar Windpipe and Wind Chimney (Case Study: Rasoulian House of Yazd).
Cooling is one of the most influential factors to provide thermal comfort. The inactive cooling systems for residential environments can help us consume non-renewable natural resources. The aim of this paper is to investigate the performance of solar windproof and chimney, saving in energy consumption, and reducing environmental problems. This research is implemented with a review of the Rasool...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JCP
دوره 8 شماره
صفحات -
تاریخ انتشار 2013