CHARACTERIZATION OF CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS IN AIR USING OPTICAL MEASUREMENTS Sean

نویسندگان

  • Sean T. Hansen
  • Antoni Turo
  • F. Levent Degertekin
  • Butrus T. Khuri-Yakub
چکیده

Capacitive micromachined ultrasonic transducers (CMUTs) are efficient transmitters and receivers for air-coupled nondestructive evaluation applications [l]. In this paper, we present optical measurements on CMUTs with circular and rectangular membranes. Use of a laser interferometer permits accurate measurement of individual membrane displacements as well as characterization of mode shapes on the membrane. When optical displacement measurements are combined with electrical impedance measurements, all elements of the equivalent circuit model can be evaluated. In particular, an estimate of the loss in the transducer is possible. Loss mechanisms include structural losses and squeeze-film effects of air behind the membrane, the latter of which has both frequency-shifting and dissipative effects. Recently fabricated circular and rectangular membrane designs typically exhibit a real loss on the order of 500 rayls f 200 rayls. The degree of resonant frequency shift for unsealed membranes in air depends strongly on the particular geometry, but can be as much as 30% of the transducer's resonant frequency in vacuum. Measurements of CMUT loss due to air are compared to squeeze-film theory and are included in an equivalent circuit model. This model is compared against the measurement results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capacitive micromachined ultrasonic transducers for robotic sensing applications

Ultrasonic ranging is the most common method used in robotic systems for distance or proximity sensing. The heart of the method is an ultrasonic transducer that emits and detects ultrasound. There are mainly two types of transducers existing in the market today; piezoelectric and electrostatic. In this paper, we propose the use of a new type of transducer, which is capacitive micromachined ultr...

متن کامل

Defect Imaging by Micromachined Ultrasonic Air Transducers

dynamic ranges in excess of 100 dB are attainable in pulseecho operation using commercially available discrete mmponents. Transmission experiments through aluminum and composite plates verify more than 100 dB dynamic range and demonstrate the ability of cMUTs to image defects in air at 2.5 MHz. W e also present a variation on cMUT design which improves the useful bandwidth of the device, permit...

متن کامل

Characterization and Modeling of Capacitive Micromachined Ultrasonic Transducers for Diagnostic Ultrasound

This paper describes the characterization and modeling of capacitive micromachined ultrasonic transducers (cMUTs). Computational models of the transducers were produced through the combined use of finite element analysis (FEA) and lumped element modeling. Frequency response plots were generated for both transducers in air and water environments. Through the use of laser Doppler velocimetry, tra...

متن کامل

Capacitive Micromachined Ultrasonic Transducers: Theory and Technology

Capacitive micromachined ultrasonic transducers ~CMUTs!, introduced about a decade ago, have been shown to be a good alternative to conventional piezoelectric transducers in various aspects, such as sensitivity, transduction efficiency, and bandwidth. In this paper, we discuss the principles of capacitive transducer operation that underlie these aspects. Many of the key features of capacitive u...

متن کامل

Collapsed Regime Operation of Capacitive Micromachined Ultrasonic Transducers based on Wafer-Bonding Technique

We report experimental results from collapsed regime operation of capacitive micromachined ultrasonic transducers (cMUTs) fabricated by a wafer bonding technique. The results show that a cMUT operating in the collapsed regime produces a maximal output pressure higher than a cMUT operating in the precollapse regime at 90 % of its collapse voltage, 1.79 kPa/V vs. 9.72 kPa/V at 2.3 MHz. In collaps...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005