SLEEP DISORDERED BREATHING Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea

نویسندگان

  • S D West
  • D R Jones
  • J R Stradling
چکیده

Background: The simplest method of initiating and maintaining therapeutic continuous positive airways pressure (CPAP) therapy for obstructive sleep apnoea (OSA) has not been established. Methods: Ninety eight subjects with OSA requiring CPAP treatment (more than 10 dips in oxygen desaturation of .4% per hour of sleep study and Epworth Sleepiness Score (ESS) .9) were randomised prospectively to three different methods of CPAP delivery for 6 months: (1) autotitration pressure throughout; (2) autotitration pressure for 1 week followed by fixed pressure (95th centile) thereafter; and (3) fixed pressure determined by algorithm (based on neck size and dip rate). Patients and investigators were blind to group allocation. One week after initiation the patients were routinely reviewed by sleep nurses. Study assessments took place before starting CPAP treatment and 1 and 6 months after to assess ESS, maintenance of wakefulness test, 24 hour blood pressure, general health (SF-36), and sleep apnoea related quality of life. CPAP internal monitoring data were also collected. Results: There were no significant differences in any of the outcome measures or CPAP monitoring data between the three groups. The 95th centile CPAP pressures delivered in the 6 month and 1 week autotitration groups were higher than in the algorithm group, but the median pressures were lowest in the 6 month autotitration group. Conclusions: The method of determining CPAP pressure for treatment of moderate to severe OSA makes no significant difference to clinical outcome measures. The autotitration CPAP machine used has no advantage in this setting over simpler methods of pressure determination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea.

BACKGROUND The simplest method of initiating and maintaining therapeutic continuous positive airways pressure (CPAP) therapy for obstructive sleep apnoea (OSA) has not been established. METHODS Ninety eight subjects with OSA requiring CPAP treatment (more than 10 dips in oxygen desaturation of >4% per hour of sleep study and Epworth Sleepiness Score (ESS) >9) were randomised prospectively to ...

متن کامل

SLEEP DISORDERED BREATHING Effect of increased lung volume on sleep disordered breathing in patients with sleep apnoea

Background: Previous studies have shown that changes in lung volume influence upper airway size and resistance, particularly in patients with obstructive sleep apnoea (OSA), and that continuous positive airway pressure (CPAP) requirements decrease when the lung volume is increased. We sought to determine the effect of a constant lung volume increase on sleep disordered breathing during non-REM ...

متن کامل

Effect of increased lung volume on sleep disordered breathing in patients with sleep apnoea.

BACKGROUND Previous studies have shown that changes in lung volume influence upper airway size and resistance, particularly in patients with obstructive sleep apnoea (OSA), and that continuous positive airway pressure (CPAP) requirements decrease when the lung volume is increased. We sought to determine the effect of a constant lung volume increase on sleep disordered breathing during non-REM s...

متن کامل

Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications.

Treatment of obstructive sleep apnea with nasal continuous positive airway pressure mandates simultaneous increases of both inspiratory and expiratory positive airway pressures to eliminate apneas as well as nonapneic oxyhemoglobin desaturation events. We hypothesized that the forces acting to collapse the upper airway during inspiration and expiration are of different magnitudes and that obstr...

متن کامل

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006