OBJECTIVE To assess bacteriological quality of drinking water in Punjab and to evaluate usefulness of H2S strip test in comparison with multiple tube test. METHOD Samples of water were tested using H2S strips and multiple tube test. RESULTS Maximum bacterial contamination was observed in water from domestic pumps (95.83%). Followed by tap water in rural areas of Punjab (91.30%) and tap water in Lahore (42.85%). Bacterial contamination was significantly higher (p < 0.001) in rural areas as compared to urban areas. Comparison of results of testing water samples by H2S strip test and multiple tube test revealed that H2S strip is 87.24% sensitive and 100% specific for detection of bacterial contamination with a positive predictive value of 100%. It was also observed that 100% water samples negative for total coliforms were also negative by H2S strip method. Moreover, with increase in number of total coliforms in the water samples, positivity by H2S strip method also increased (samples with more than 10 total coliforms/100 ml were 100% positive by H2S strip method). Therefore, H2S strip test can be used as alternative to multiple tube test for detection of bacterial contamination of water supplies. CONCLUSION It is concluded that bacterial contamination of water is a significant problem in Punjab. It can be improved by regular monitoring of water supplies. For this purpose use of H2S strip test is advocated at house hold level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified H2S Paper Strip Test for Detection of Bacteriological Contamination in Drinking Water

The provision of safe drinking water to all is the priority item in the agenda of Government of India. To fulfill this requirement thousands of bore well installed in the villages. Despite of this, large population still depends upon the dug well water; shallow bore well and untreated surface waters for their drinking water needs. Hence there is need to monitor the bacteriological quality of wa...

متن کامل

Determination of Bacteriological and Physiochemical Parameters of Drinking Water of Gorgan city, Iran ( 2010)

Abstract Background and objectives: Microbial, physical and chemical properties of drinking water, considering type and quantity of the drinking water, are the factors for determining the acceptability of water. The effect of each of the above components on increasing the quality of water or threatening the health of consumers is also considerable. We aimed to investigate the trace amounts of m...

متن کامل

Quality Analysis of Drinking Water Provided for the Readymade Garment Workers in Dhaka, Bangladesh

Readymade garment industries are the prominent economic sector for Bangladesh as well as scoping the huge working area for workers. But health condition of workers, drinking water quality, and proper maintenance of the environmental parameters are not well monitored. This study aims to assess the physio-chemical and bacteriological quality of drinking water provided for the garment workers in D...

متن کامل

Quality Analysis of Drinking Water Provided for the Readymade Garment Workers in Dhaka, Bangladesh

Readymade garment industries are the prominent economic sector for Bangladesh as well as scoping the huge working area for workers. But health condition of workers, drinking water quality, and proper maintenance of the environmental parameters are not well monitored. This study aims to assess the physio-chemical and bacteriological quality of drinking water provided for the garment workers in D...

متن کامل

تعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN

Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 49 10  شماره 

صفحات  -

تاریخ انتشار 1999