Results The mean intubation time using IGI was shorter (p < 0.017) than that of IBRI and MCL in both endotracheal tubes (17.6 vs. 29.3 vs. 20.2 in conventional PVC tube; 14.6 vs. 27.4 vs. 19.9 in wire-reinforced silicone tube; sec). There were no significant (p > 0.05) differences between conventional PVC and wire-reinforced silicone tube for each intubation technique. The cumulative success rate using IGI was also shorter (p < 0.017) than that of IBRI and MCL in both endotracheal tubes.
منابع مشابه
Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملComparison of blind intubation through supraglottic devices and direct laryngoscopy by novices: a simulation manikin study
OBJECTIVE This study aimed to compare intubation performance between blind intubation through supraglottic airway devices and direct laryngoscopy by novices under manikin simulation. We hypothesized that the intubation time by novices using supraglottic airway devices was superior to that with the Macintosh laryngoscope (MCL). METHODS A prospective, randomized crossover study was conducted wi...
متن کاملA comparative Study of Tracheal Intubation through i-gel® and Intubating
In this prospective randomized study, success rate of blind tracheal intubation through two different supraglottic airway devices viz. i-gel ® and the intubating laryngeal mask airway (ILMA)® was compared a using conventional polyvinylchloride endotracheal tubes. Eighty patients undergoing elective surgery under general anaesthesia were randomized in two groups comprising of 40 patients each to...
متن کاملComparison of learning performance of 2 intubating laryngeal mask airways in novice
BACKGROUND Intubating laryngeal mask airways (LMAs) such as i-gel and Aura-i could serve as rescue devices in resuscitation and further ensure the airway by facilitating trachea intubation without ventilation interruption. But data regarding intubating LMAs in novice are limited and skill degeneration without regular training has not been evaluated. So we designed this prospective randomized cr...
متن کاملComparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative sore Throat: A Randomized Controlled Trial
Introduction: Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed. Materials and Methods: ...