Measures to reduce radiation in a modern cardiac catheterization laboratory.
نویسندگان
چکیده
BACKGROUND X-ray use in the catheterization laboratory is guided by the principle of as low as reasonably achievable. In accordance with this principle, we reduced the default fluoroscopic frame rate from 10 to 7.5 frames/s and increased the emphasis on the use of low-dose acquisition starting January 1, 2013. We aimed to study the impact of these measures on the total air kerma during diagnostic catheterization (DC) and percutaneous interventions (PCI). METHODS AND RESULTS Propensity matching based on age, sex, body surface area, total fluoroscopy time, and total acquisition time was used to select matched patients for 2012 and 2013, further stratified by DC or PCI. The total air kerma was subsequently compared between 2012 and 2013, separately for DC and PCI. Median total air kerma during DC in 2013 was 625 mGy, which was significantly lower than the corresponding values in 2012 (median, 798 mGy; P<0.001). Similarly, median total air kerma during PCI in 2013 was 1675 mGy, which was significantly less than corresponding values in 2012 (median 2463 mGy, P<0.001). On comparison of air kerma rates between corresponding projections in 2 years, we observed a significant reduction in fluoroscopy- and acquisition-based air kerma rates in 2013, after institution of radiation reduction measures in all projections. CONCLUSIONS With reduction in the default fluoroscopic frame rate and a greater use of low-dose acquisition, there has been a marked reduction in the total air kerma and air kerma rates for DC and PCI.
منابع مشابه
SCAI consensus document on occupational radiation exposure to the pregnant cardiologist and technical personnel.
Concerns regarding radiation exposure and its effects during pregnancy are often quoted as an important barrier preventing many women from pursuing a career in Interventional Cardiology. Finding the true risk of radiation exposure from performing cardiac catheterisation procedures can be challenging and guidelines for pregnancy exposure have been inadequate. The Women in Innovations group of Ca...
متن کاملCancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report.
BACKGROUND Occupational doses from fluoroscopy-guided interventional procedures are the highest ones registered among medical staff using x-rays. The aim of the present study was to evaluate the order of magnitude of cancer risk caused by professional radiation exposure in modern invasive cardiology practice. METHODS From the dosimetric Tuscany Health Physics data bank of 2006, we selected do...
متن کاملRelationship of beam angulation and radiation exposure in the cardiac catheterization laboratory.
OBJECTIVES The aim of this study was to analyze the relationship between beam angulation and air kerma in a modern cardiac catheterization laboratory. BACKGROUND Recent reports have identified the merits of reducing radiation scatter, an important determinant of radiation dose in the catheterization laboratory. Radiation scatter is poorly characterized in the context of catheterization labora...
متن کاملPulse fluoroscopy radiation reduction in a pediatric cardiac catheterization laboratory.
OBJECTIVE To determine if lower starting pulse fluoroscopy rates lead to lower overall radiation exposure without increasing complication rates or perceived procedure length or difficulty. SETTING The pediatric cardiac catheterization laboratory at University of Michigan Mott Children's Hospital. PATIENTS Pediatric patients with congenital heart disease. DESIGN/INTERVENTIONS We performed ...
متن کاملRadiation safety program for the cardiac catheterization laboratory.
The Society of Cardiovascular Angiography and Interventions present a practical approach to assist cardiac catheterization laboratories in establishing a radiation safety program. The importance of this program is emphasized by the appropriate concerns for the increasing use of ionizing radiation in medical imaging, and its potential adverse effects. An overview of the assessment of radiation d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2014