Implantable cardioverter-defibrillators in patients with hypertrophic cardiomyopathy -- dilemmas and difficulties.

نویسندگان

  • Andrzej Przybylski
  • Longina Małecka
  • Mariusz Pytkowski
  • Lidia Chojnowska
  • Michał Lewandowski
  • Maciej Sterliński
  • Aleksander Maciag
  • Witold Ruzyłło
  • Hanna Szwed
چکیده

INTRODUCTION The implantation of a cardioverter-defibrillator (ICD) is an established method of sudden cardiac death (SCD) prevention. The value of ICD therapy in secondary prevention of SCD is unquestionable. Precise identification of high-risk patients and ICD use for primary prevention of SCD, especially in patients with hypertrophic cardiomyopathy (HCM), remain controversial. Problems include the high prevalence of complications associated with ICD implantation and optimal selection of ICDs. AIM To estimate the frequency and type of complications after ICD implantations in HCM patients in a long-term follow-up. METHOD The efficacy and safety of ICD therapy were estimated in 46 HCM patients with devices implanted for a secondary (n-18) or primary prevention (n-28) of SCD. RESULTS During the mean follow-up period of 28.2+/-26.1 months (from 2 to 68) appropriate ICD interventions occurred in 10 (55%) patients of the secondary prevention group and in 3 (10%) patients of the primary prevention group. Complications were documented in 15 (33%) patients. The most frequent were inappropriate ICD interventions recorded in 14 (30%) patients. The causes of these inappropriate ICD shocks were: T-wave oversensing (7 patients), atrial fibrillation with rapid ventricular rhythm (3 patients), lead failure (2 patients), and sinus tachycardia (2 patients). In two patients infections of the ICD pocket requiring removal of the system occurred. Displacement of the lead occurred in one patient. There were no significant differences in the prevalence of complications between the primary and secondary prevention groups or in the number of inappropriate interventions with respect to ICD type. CONCLUSIONS The high rate of appropriate ICD shocks provides proof of high ICD-based SCD prevention efficacy. There is a high rate of complications observed after ICD implantation with inappropriate interventions being the most frequent among them. This indicates that careful programming of the device as well as the use of a programme with T-wave oversensing prevention should be ensured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Implantable Cardioverter Defibrillators in the Treatment of Hypertrophic Cardiomyopathy

Hypertrophic cardiomyopathy (HCM) is an important cardiovascular disease with sudden cardiac death as the most devastating presentation. Implantable cardioverter defibrillators (ICD) are the optimal therapy for prevention of sudden death from ventricular tachycardia or fibrillation of any cause. While there is no controversy with implanting ICDs in patients who have already survived a cardiac a...

متن کامل

Life expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy

CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...

متن کامل

Life expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy

CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...

متن کامل

Surface fragmented QRS in a patient with hypertrophic cardiomyopathy and malignant arrhythmias: Is there an association?

An 18- year old woman with hypertrophic cardiomyopathy, aborted sudden cardiac death and implanted with an implantable cardioverter defibrillator (ICD), developed progressive fragmentation of her surface 12-lead electrocardiogram (ECG). During the follow-up, she presented with multiple appropriate ICD discharges. Here, we discuss the possible association between surface fragmented ECG and the r...

متن کامل

Atypical position of subcutaneus implantable cardioverter-defibrillator as a solution in hypertrophic cardiomyopathy patient with initially negative electrocardiographic screening.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehv209 Online publish-ahead-o...

متن کامل

Implantable cardioverter-defibrillator in pregnant women with hypertrophic cardiomyopathy.

We describe the successful implantation of a cardioverter-defibrillator (ICD) in two pregnant women with hypertrophic cardiomyopathy at high risk. The indication of ICD and the necessary care for ICD implantation during pregnancy are discussed and were the main objectives of this case report.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 63 4  شماره 

صفحات  -

تاریخ انتشار 2005